7.Take care when discharging air from the tank, i.e. from the safety valve, the drain cock or the air outlet. Compressed air can be extremely dangerous. Take care the discharge air does not cause dust, stones or any other foreign particles to be blown through the air and that the air is discharged in a safe manner.
Troubleshooting
Trouble | Possible cause | Possible remedy | |
|
|
| |
Motor will not run, running too | Power fault or supply voltage too low | Check the power supply | |
slow or becoming excessively hot |
|
| |
Power cord too long or too thin | Use authorised service centre | ||
| |||
|
| to replace the power cord | |
|
|
| |
| Faulty pressure switch | Use authorised service centre | |
|
| to repair or replace the switch | |
|
|
| |
| Faulty motor | Use authorised service centre | |
|
| to repair or replace the motor | |
|
|
| |
| Main compressor sticking/tight | Use authorised service centre | |
|
| to repair or replace faulty parts | |
|
|
| |
Main compressor sticking/tight | Moving parts damaged by heat | Use authorised service centre to | |
| due to insufficient lubrication | check crankshaft, bearings, con rod, | |
|
| piston rings, etc and replace | |
| Moving parts damaged or blocked | ||
| where necessary | ||
| by foreign particle | ||
|
| ||
|
|
| |
Vibration or abnormal noise | Loose part | Use authorised service centre | |
|
| to check and repair if necessary | |
|
|
| |
| Foreign body in main compressor | Use authorised service centre | |
|
| to check and clean if necessary | |
|
|
| |
| Piston connecting with the valve seat | Use authorised service centre | |
|
| to increase size of gasket | |
|
|
| |
| Moving parts excessively worn | Use authorised service centre | |
|
| to repair or replace | |
|
|
| |