TROUBLESHOOTING
Problem | Possible Cause | Solution |
|
|
|
Compressor will not run | Loss of power or overheating | Check for proper use of extension |
|
| cord |
| No electrical power | Check to be sure unit is plugged in |
|
| Check fuse/breaker or motor over- |
|
| load |
| Blown shop/house fuse | Replace shop/house blown fuse |
| Shop/house breaker open | Reset shop/house breaker, determin- |
|
| ing why problem happened |
| Thermal overload open | Motor will restart when cool |
| Pressure switch bad | Replace pressure switch |
| Tank is full of air | Compressor will turn on when tank |
|
| pressure drops to |
|
|
|
Motor hums but cannot run or runs | Low voltage | Check with voltmeter |
slowly | Wrong gauge wire or length of exten- | Check for proper gauge wire and |
| ||
| sion cord | cord length |
| Shorted or open motor winding | Take compressor to service center |
| Defective check valve or unloader | Take compressor to service center |
Fuses blow/circuit breaker trips | Incorrect size fuse, circuit overload | Check for proper fuse, use time- |
repeatedly |
| delay fuse, disconnect other electri- |
|
| cal appliances from circuit or operate |
|
| compressor on its own branch circuit |
| Wrong gauge wire or length of exten- | Check for proper gauge wire and |
| sion cord | cord length |
| Defective check valve or under loader | Take compressor to service center |
Thermal overload protector cuts out | Low voltage | Check with voltmeter |
repeatedly | Lack of proper ventilation/room tem- | Move compressor to |
| ||
| perature too high | area |
| Wrong gauge wire or length of exten- | Check for proper gauge wire and |
| sion cord | cord length |
Air receiver pressure drops when | Loose connections (fittings, tubing, | Check all connections with soap and |
compressor shuts off | etc.) | water solution and tighten |
| Loose drain valve | Tighten drain valve |
| Check valve leaking | Take compressor to service center |
|
| DANGER: |
|
| Do not disassemble check valve |
|
| with air in tank — bleed tank. |
|
|
|
Excessive moisture in discharge air | Excessive water in air tank | Drain tank |
| High humidity | Move to area of less humidity; use air |
|
| line filter |
Compressor runs continuously | Defective pressure switch | Take compressor to service center |
| Excessive air usage | Decrease air usage; compressor not |
|
| large enough for tool’s requirement |
Compressor vibrates | Loose mounting bolts | Tighten mounting bolts |
Air output lower than normal | Broken inlet valves | Take compressor to service center |
| Connections leaking | Tighten connections |