Extension Cords
CAUTION: Use only extension cords marked for outdoor use.
WARNING: Inspect extension cords often and replace if damaged.
Be sure to use the right size extension cord. If cord size is wrong, tool may be damaged. Tool performance may also be affected.
Extension Cord Size Requirement
1 to 25 feet, use 16 AWG rated cord
26 to 50 feet, use 14 AWG rated cord
Loading Tool
WARNING: Never load tool while it is plugged in. Accidental discharge may occur. Before loading, toggle power switch to the OFF (0) position and unplug tool.
1. | Toggle power switch to the OFF |
|
| (0) position (see Figure 1) and |
|
| unplug tool. |
|
2. | Press in latch lock and slide | Latch Lock |
| magazine back until fully open | |
| (see Figure 2). |
|
3.Lay tool on its side with view window facing upward (see Figure 3).
4. Load staples/nails on track (see |
|
Figure 3). Make sure staples/nails | Magazine |
are forward in the magazine and | |
staple/nail points are toward bot- |
|
tom of tool. | Figure 2 |
ON/OFF |
| |
Switch In | View Window | |
Off Position | Loaded Staples (Shown)/Nails | |
| ||
Figure 1 | (Points Toward Bottom of Tool) | |
Figure 3 | ||
| ||
| Continued |
116261 | 5 | www.desatech.com |