RIDGID OL50135W manual Troubleshooting, Problem Cause Solution

Page 18

TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Compressor will not run

Loss of power or overheating

Check for proper use of extension

 

 

cord

 

No electrical power

Check to be sure unit is plugged in

 

 

Check fuse/breaker

 

Blown shop/house fuse

Replace shop/house blown fuse

 

Shop/house breaker open

Reset shop/house breaker, determining

 

 

why problem happened

 

Thermal overload open

Motor will restart when cool

 

Pressure switch bad

Replace pressure switch

 

Tank is full of air

Compressor will turn on when tank

 

 

pressure drops to cut-in pressure

 

 

 

Motor hums but cannot run or runs

Low voltage

Check with voltmeter

slowly

Wrong gauge wire or length of exten-

Check for proper gauge wire and cord

 

 

sion cord

length

 

Shorted or open motor winding

Take compressor to service center

 

Defective check valve or unloader

Take compressor to service center

 

 

 

Fuses blow/circuit breaker trips

Incorrect size fuse, circuit overload

Check for proper fuse, use time-delay

repeatedly

 

fuse, disconnect other electrical appli-

 

 

ances from circuit or operate compres-

 

 

sor on its own branch circuit

 

Wrong gauge wire or length of exten-

Check for proper gauge wire and cord

 

sion cord

length

 

Defective check valve or under loader

Take compressor to service center

 

 

 

Thermal overload protector cuts out

Low voltage

Check with voltmeter

repeatedly

Lack of proper ventilation/room tem-

Move compressor to well-ventilated

 

 

perature too high

area

 

Wrong gauge wire or length of exten-

Check for proper gauge wire and cord

 

sion cord

length

18

Image 18
Contents OPERATOR’S Manual OIL Lubricated Direct DriveTable of Contents IntroductionPersonal Safety General Safety RulesElectrical Safety Work AreaSpecific Safety Rules ServiceSymbols Symbol Name DESIGNATION/EXPLANATIONSymbol Signal Meaning Extension Cords Speed and WiringElectrical Grounding InstructionsGlossary of Terms NPTScfm Features Product SpecificationsHandle BUILT-IN Cord Safety Wrap Valve Assembly Attaching a Hose Drain Valves Switch HoseBreaking in the Pump See Figures 4RAISING/LOWERING the Handle OperationApplications Handle Release Knob BUILT-IN Cord WrapChecking the OIL See Figures 8OIL Dipstick OIL Fill Hole Using the AIR Compressor Cold Weather StartingSee Figures 10 Draining the Tanks Checking the Safety ValveTank Drain Valves Safety To drainMaintenance General MaintenanceReplacing the AIR Filter Wheel Spacer HEX NUT Changing the OILSee Figures 15 OIL Fill Hole Drain Plug HEX KEYTroubleshooting Problem Cause SolutionTroubleshooting Page Warranty Customer Service Information Model No OL50135W Serial No