RIDGID OL50135W manual Using the AIR Compressor, Cold Weather Starting, See Figures 10

Page 14

OPERATION

USING THE AIR COMPRESSOR

See Figures 10 - 11.

nEnsure power switch is in the OFF (O) position and air compressor is unplugged.

nIf not already installed, attach hose to compressor as previously instructed.

nAttach 1/4 in. NPT male connector fitting to accessory or tool you intend to use.

nInsert the other end of the male connector to the quick coupler on the open end of hose.

WARNING:

Always ensure the switch is in the OFF (O) position and the regulator pressure gauge reads zero before changing air tools or disconnecting the hose from the air outlet. Failure to do so could result in possible serious personal injury.

nConnect the power cord to the power supply.

nTurn the switch ON ( l ).

nRotate pressure regulator knob to desired line pressure. Turning the knob clockwise increases air pressure at the outlet; turning counterclockwise reduces air pressure at the outlet.

nFollowing all safety precautions in this manual and the manufacturer’s instructions in the air tool manual, you may now proceed to use your air-powered tool.

WARNING:

Your tool may require more air consumption than this air compressor is capable of providing. Check the tool manual to avoid damage to the tool or risk of personal injury.

nControl the amount of air flow with the pressure regula- tor knob. Turning the knob fully counterclockwise will completely stop the flow of air.

NOTE: Always use the minimum amount of pressure necessary for your application. Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently.

nWhen finished, always drain the tank and unplug the unit. Never leave the unit plugged in and/or running unat- tended.

SWITCH

 

 

Fig. 10

 

PRESSURE

 

TANK

REGULATOR

 

KNOB

REGULATOR

PRESSURE

 

PRESSURE

GAUGE

 

 

GAUGE

 

 

Fig. 11

COLD WEATHER STARTING

nTurn the switch to the OFF (O) position.

nTurn the tank drain valves counterclockwise to open.

NOTE: The air compressor has two tanks. Be sure to open both tank drain valves.

nPull the switch out to the ON ( l ) position and run the compressor for 1 - 2 minutes.

nTurn the switch to the OFF (O) position.

nTurn the tank drain valves clockwise to close.

NOTE: The air compressor has two tanks. Be sure to close both tank drain valves.

nFollow normal operating procedures.

14

Image 14
Contents OPERATOR’S Manual OIL Lubricated Direct DriveTable of Contents IntroductionPersonal Safety General Safety RulesElectrical Safety Work AreaSpecific Safety Rules ServiceSymbols Symbol Name DESIGNATION/EXPLANATIONSymbol Signal Meaning Extension Cords Speed and WiringElectrical Grounding InstructionsScfm Glossary of TermsNPT Handle BUILT-IN Cord Safety Wrap Valve FeaturesProduct Specifications Assembly Attaching a Hose Drain Valves Switch Hose Breaking in the Pump See Figures 4RAISING/LOWERING the Handle OperationApplications Handle Release Knob BUILT-IN Cord WrapOIL Dipstick OIL Fill Hole Checking the OILSee Figures 8 See Figures 10 Using the AIR CompressorCold Weather Starting Draining the Tanks Checking the Safety ValveTank Drain Valves Safety To drainReplacing the AIR Filter MaintenanceGeneral Maintenance Wheel Spacer HEX NUT Changing the OILSee Figures 15 OIL Fill Hole Drain Plug HEX KEYTroubleshooting Problem Cause SolutionTroubleshooting Page Warranty Customer Service Information Model No OL50135W Serial No