Emerson Essential Accessories for Air Compressors: 023-0060-18 and 943-0024-01 Parts Overview

Page 19

Application Engineering

 

 

 

 

B U L L E

T

I

N

AE4-1395

Table 4 – Compressor Accessories

Part

Part Description

Part Number

Models

Notes

Category

 

 

 

 

 

Copeland Scroll Digital

943-0024-01

All

For OEM applications

 

Compressor Controller

 

 

 

 

 

Emerson Commercial Comfort

943-0175-00

All

For retrofit applications

 

Controller

 

 

 

 

 

Modulation Valve & 24V Coil

998-0061-19

 

 

 

24V Coil Only

023-0060-18

 

Tubing kit is for 7/8"

 

110V Coil Only

TBD

ZPD34-54K5

 

compressor suction; all coils

Modulation

220V Coil Only

TBD

ZPD61-91KC

have 1/4" spade electrical

 

Modulation Valve, 24V Coil,

998-0090-02

ZRD34-81KC

terminals

 

Tubing Kit

 

 

 

 

 

 

 

Modulation Valve & Tubing Kit

998-0090-01

 

 

 

Modulation Valve

910-0109-00

 

 

 

24V Coil

998-0060-03

ZPD103-182KC

All coils have 1/4" spade

 

120V Coil

998-0060-04

ZRD94-125KC

electrical terminals

 

200/220V Coil

998-0060-05

 

 

Mounting

 

 

 

 

Crankcase

 

 

 

 

Heaters

Refer to the application engineering bulletins for the equivalent non-digital compressor model for

Oil

parts in these categories. Or, refer to the "service parts" section at www.EmersonClimate.com

Electrical

 

 

 

 

Tandems

 

 

 

 

 

 

 

ZPD34-54K5

 

 

 

985-0199-00

ZPD61-83KC

Fits 1/2" discharge tube

Diagnostics

 

 

ZRD36-72KC

 

Discharge Line Thermistor

 

ZPD103-182KC

 

& Protection

985-0200-00

Fits 7/8" discharge tube

 

 

 

ZRD94-125KC

 

 

 

085-0204-00

ZPD91KC

Requires clamp 032-0689-00,

 

 

ZRD81KC

fits any size tube

 

 

 

 

Commercial Comfort

 

ZPD34-54K5

Thermistor 085-0204-00 and

 

 

ZPD61-91KC

clamp 032-0689-00 must

 

Controller, Modulation Valve,

980-7000-00

 

ZRD36-48KC

be used with ZRD81KC and

 

24V Coil, & Tubing Kit

 

Retrofit Kits

 

ZRD61-81KC

ZPD91KC applications

 

Commercial Comfort

 

ZPD103-182KC

 

 

Controller, Discharge

980-7000-01

 

 

ZRD94-125KC

 

 

Thermistor, & 24V Coil

 

 

 

 

 

 

The contents of this publication are presented for informational purposes only and they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. Emerson Climate Technologies, Inc. reserves the right to modify the designs or specifications of such products at any time without notice. Emerson Climate Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Climate Technologies, Inc. product remains solely with the purchaser and end-user.

© 2012 Emerson Climate Technologies, Inc.

19

Printed in the U.S.A.

 

Image 19
Contents Introduction SafetyAssembly Line Procedures Service ProceduresSafety Icon Explanation Safety InstructionsBurn Hazard Safety StatementsElectrical Shock Hazard Pressurized System HazardApplication Considerations 410A 22 & R-407CNomenclature Digital Compressor Operation How it WorksPiping Sound CharacteristicsSolenoid Valve and Coil Pressure FluctuationsOil Type and Oil Removal Scroll Temperature ProtectionPower Factor Crankcase HeatersDigital Compressor Retrofit Applications Modulation ControlApplication Tests Oil Level VerificationCompressor Selection & Change-Out Retrofit Applications To AvoidPerformance Modeling System ModificationsAssembly Line Procedures To 15 Ton Modulation Valve Replacement Procedure Service ProceduresModulation Troubleshooting To 7.5 Ton Modulation Valve Replacement ProcedureForm No Copeland Scroll Compressor Functional Check50% Loaded 80% Loaded To 15 Ton Digital Scroll Cross Sectional View ZPD34-54K5 22, R-407C, R-410A Operating EnvelopeCompressor Capacity Graph Discharge Thermistors Second Operating Cycle AE4-1395To 7.5 Ton Tandem Yes Part Refrigerant Charge Limits Model PoundsFoot-Pounds Inch-Pounds TBD