18.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws In a clockwise sequence. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws,
CEILING
AT LEAST
7'
SWITCH HOUSING ASSEMBLY
Figure 26
FLOOR
SETSCREW
COLLAR
Figure 24
!WARNING
To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades, or cleaning the fan.
19.Reinstall the switch housing assembly by passing the wires from the motor shaft through the collar, screw the assembly onto the motor shaft (Figure 24). Tighten the setscrew using the 5/32” hex wrench (supplied). Engage the connector from the switch housing to the motor connector. The two connectors are keyed and must be mated correctly before they can be engaged (Figure 25).
| MOTOR |
SWITCH HOUSING | CONNECTOR |
CONNECTOR |
|
COLLAR
SETSCREW
SWITCH HOUSING
ASSEMBLY
Figure 25
!WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 26).
!WARNING
The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.
20.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 27).
!WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
!WARNING
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
OUTLET
BOX
TWO SCREWS |
|
SUPPLIED WITH | HANGER |
OUTLET BOX | |
| BRACKET |
| TAB |
Figure 27
21.Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 28). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 27).
!WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.