Emerson CF2500HTW01, CF2500S01, CF2500TG01, CF2500OB01 Attaching Light Kit, Using Your Ceiling Fan

Page 12

5.Slip the pull chain through the bushing in the switch housing cover assembly (Figure 31). Position the cover assembly on the switch housing assembly with the reversing switch lever positioned in the slot provided. Secure the cover assembly to the switch housing assembly using four 8-32 x 3/8” flat head screws (provided).

6.Slip the switch pull chain through the hole in the pendant (supplied), then secure the pendant by snapping the coupling (supplied) onto the end of the chain.

Attaching Light Kit

To install an Emerson accessory light kit, remove the four screws securing the switch housing cover assembly to the switch housing. Remove the trim medallion from the bottom of the switch housing cover (Figure 32). Attach the light kit to the switch housing cover assembly with the lockwasher and nut supplied with the light kit (Figure 33). Install the light kit in accordance with the Emerson light kit Owner's Manual.

TRIM MEDALLION

REVERSING

SWITCH LEVER

SWITCH HOUSING

COVER ASSEMBLY

Figure 31

BUSHING

PULL CHAIN

8-32 X 3/8"

FLAT HEAD SCREW (4)

SWITCH HOUSING

ASSEMBLY

 

REMOVE

REMOVE

HEX

SCREW

FLAT HEAD

 

SCREW (4)

 

SWITCH HOUSING

COVER ASSEMBLY

REMOVE

TRIM

MEDALLION

Figure 32

Using Your Ceiling Fan

1.Restore electrical power to the outlet box by turning the electricity on at the main fuse box.

2.When controlled by a wall switch check the operation of the fan by gently pulling on the 4-position speed control pull chain switch. The operating sequence is as follows:

!WARNING

To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.

SWITCH HOUSING

COVER ASSEMBLY

LOCKWASHER AND NUT (SUPPLIED WITH LIGHT KIT)

REVERSING SWITCH

SPEED CONTROL SWITCH PULL CHAIN

LIGHT KIT

Figure 33

THREE-SPEED 1st Pull — HIGH 2nd Pull — Medium 3rd Pull — Low 4th Pull — OFF

3.When operated by an Emerson Remote Control, check operation of fan and light in accordance with the Remote Control Owner’s Manual.

4.If airflow is desired in opposite direction, turn your fan off and wait for the blades to stop turning. Then slide the reversing switch to the opposite position and turn fan on again. The fan blades will turn in the opposite direction and reverse the airflow.

12

Image 12
Contents Botanica Series Safety Instructions Tools Needed for Assembly Unpacking InstructionsElectrical Requirements UplightKnurled Knob Motor Coupling Cover Wire Connectors PIN Hanger Ball Downrod Setscrew Ceiling Cover Supply Wires Section B See Section a Switch Housing Final Assembly Using Your Ceiling Fan Attaching Light KitTrouble Shooting MaintenanceRepair Parts AccessoriesRepair Parts List Botanica Models DescriptionLimited Warranty