Sierra Monitor Corporation 4105 manual Hcn

Page 15

Instruction Manual

8.SPECIFICATIONS (Cont.) Cross Sensitivities (toxic sensors)

Model

Gas

Reading from 100 ppm of interfering gas

 

 

 

 

 

Number

Type

CO

H2S Cl2

H2

SO2

NO2

NO

HCl

HCN

C2H4

4105-04

CO

100

315

-15

<40

50

-55

30

2

40

<50

4105-05

H2S

<0.5

100

-20

<0.1

<15

-15

0

0

0

0

4105-06

Cl2

0

<-10

100

0

0

105

0

0

0

0

4105-07

H2

<1

<20

0

100

3

0

35

3

35

85

4105-10

SO2

<1

0

-40

0

100

-100

0

0

15

0

4105-12

N O 2

0

-20

90

0

0

100

0

0

-3

0

4105-21

HCl

0

75

-10

0

35

-2

0

100

-8

0

4105-22

HCN

<0.5

 

-50

0

160

-190

-5

30

100

<1

4105-25

N H

0

0

0

-

40

0

0

-

-

-

 

3

 

 

 

 

 

 

 

 

 

 

4105-26

HF

0

0

9

0

9

5

-

6

-

-

Page: 12

Model 4105 Gas Sensor Module (12/02)

Image 15
Contents Model 4105 Series Applicability & Effectivity Table of Contents Section Product Description Preventative Maintenance Introduction WiringWire Gauge Maximum Length Recommended Wire/Cable GaugeQuick Start Transmitter Cover Plate Model 4105 Gas Sensor Module 12/02 OperationCalibration Service 4c Electrochemical Oxygen and Toxics 4b LEL Sensor Fault Supervision4d Missing Electromechanical Sensor Fault Supervision 4a. CombustiblesSensor Locations InstallationExplosion Proof Installation Power SupplyOxygen Wiring Diagram Model 4105 Gas Sensor Module 12/02 CombustibleToxics Specifications Sensor Type Units Range Resolution Response TimeHCN Limitedwarranty Replacement PartsAppendix a Unity Gain Mode Appendix B L.C.D. Readout Calibration ProcedureAppendix C End of Sensor Life Indication Appendix C Combustible Gas Scaling Factors Table Factor Combustible GAS Scaling Factors