Omega manual FTB600B Series Operating Parameters, Temperature, Flow Ranges

Page 7

FTB600B Series

2

Operating Parameters

Section 2. - Operating Parameters

A. Temperature

Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards.

B. Flow Ranges

The FTB600B Series is available in six different sizes, which cover a flow range from 0.1 to 120 lpm.

Specific flow ranges

FTB601B

0.1 to 2 lpm

(0.03 to 0.53 gpm)

FTB602B

0.3 to 9 lpm

(0.08 to 2.38 gpm)

FTB603B

0.5 to 15 lpm

(0.13 to 3.96 gpm)

FTB604B

1.0 to 30 lpm

(0.26 to 7.93 gpm)

FTB605B

2.5 to 75 lpm

(0.66 to 19.8 gpm)

FTB606B

4.0 to 120 lpm

(1.32 to 32 gpm)

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

 

 

 

Over range may permanently damage the flow meter.

3

Image 7
Contents User’sGuide Servicing North America Section FTB600B Series Ultra-Low Flow SensorsFTB600B Series Ultra-Low Flow Sensors Principle of Operation FTB600B Series InstallationIntroduction General DescriptionMaterial of construction Material Characteristics of PvdfFTB600B Series Operating Parameters TemperatureFlow Ranges FTB600B Series Filter Recommendations Recommended ViscosityFTB600B Series Silicone Treatment Supply Voltage FTB600B Series Infrared SensorsFrequency Output Cable Requirements Frequency Ranges forFTB600B Series Infrared Sensors Page Supply Voltage and Signal Output Connections Piping Table FTB600B Series Installation FTB600B Series Specifications KPa Liters/minute FTB600B Series Pressure Drop CurvesKPa FTB600B Series Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine Flowmeter FTB604 160 140 120 100 180 160 140 120 100 WARRANTY/ Disclaimer PH/CONDUCTIVITY Shop online at omega.com