HANGER BALL/

BLADE FLANGE

DOWNROD ASSEMBLY

SCREWS

 

CEILING

COVER

CLEVIS

 

CLEVIS

PIN

 

PIN

SETSCREW

 

HAIRPIN

 

 

CLIP

 

 

SETSCREW

 

 

BLADE ASSEMBLY

Figure 1

MOTOR COUPLING

Figure 3

 

4.Reinstall the two setscrews in the motor coupling. While pulling up on the hanger ball, securely tighten the setscrews. (Figure 1).

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

5.The fan comes with the blue, black, and white leads that are 80” long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

6.Turn fan assembly upside down in preparation for mounting fan blade assemblies.

IMPORTANT: THE SIDE OF THE FAN BLADE HAVING THE RIB LINE MUST BE FACING UPWARDS AS SHOWN IN FIGURE 2.

7.Mount blade flanges to fan blades using three 3/16- 24 x 1/2" screws per blade (Figure 2).

3/16-24 x 1/2" SCREW (3)

BLADE FLANGE

NOTE: Take care not to scratch fan housing when installing blades.

9.You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and the electrical wiring of your fan.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

RIB LINE

THIS SIDE UP

Figure 2

FAN BLADE

 

!WARNING

To reduce the risk of personal injury, do not bend the blade flanges when installing the blades or cleaning the fan. Do not insert foreign objects between rotating fan blades.

8.Attach blade assembly to motor hub using two 1/4-20 x 7/16" blade flange screws. Make sure the screws are tightened securely (Figure 3). Repeat this procedure for other four blade assemblies.

4

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Image 4
Contents Model No Safety Instructions Tools Needed for Assembly How to Put Your Ceiling Fan TogetherThis Manual is Designed to Make it as Easy as Unpacking InstructionsElectrical Requirements How to Hang Your Ceiling Fan How to Wire Your Ceiling FanUsing Your Ceiling Fan Maintenance Trouble ShootingAccessories Repair Parts Listing Service Part NoAir Comfort Products Model Description

CF742PFWW, CF742PFOB specifications

The Emerson CF742PFOB and CF742PFWW are remarkable ceiling fans designed to enhance both the aesthetic appeal and functionality of indoor spaces. These models are part of Emerson's dedication to quality and innovation, providing style, efficiency, and versatility for a variety of settings.

One of the main features of the CF742PFOB (Oil Rubbed Bronze finish) and CF742PFWW (White finish) is their sleek, modern design, which complements any décor. Their five-blade configuration, measuring 54 inches in diameter, ensures optimal airflow, making them ideal for large rooms. The design is not only visually appealing but also functional, contributing to improved air circulation and comfort throughout the space.

Both models are equipped with Emerson's exclusive EcoMotor technology, which delivers high performance while consuming significantly less energy compared to traditional ceiling fans. This efficient motor ensures quiet operation, allowing users to enjoy a peaceful environment without distracting noise. The fans operate on three distinct speeds, allowing homeowners to customize their comfort levels.

Another notable characteristic is the stylish blade design, crafted from high-quality materials for durability and longevity. The blades are angled precisely to maximize airflow while minimizing energy consumption. The reversible motor feature is an added advantage, allowing users to switch the direction of airflow, promoting cooling in the summer months and helping to circulate warm air during winter.

The CF742PFOB and CF742PFWW models also boast compatibility with various control options. They can be seamlessly integrated with remote controls or wall controls, providing convenience at the fingertips. Customers can also opt for compatible lighting kits, further enhancing the functionality of the fan while illuminating their space.

Installation is user-friendly, with a versatile mounting system that accommodates standard, angled, or flush mounting positions. This flexibility allows homeowners to install the fans in various settings, including living rooms, bedrooms, or even covered patios.

In conclusion, the Emerson CF742PFOB and CF742PFWW ceiling fans represent an excellent blend of style, efficiency, and performance. With their modern design, advanced motor technology, and versatile installation options, they serve as a perfect solution for enhancing indoor comfort while contributing to energy savings. Whether for a contemporary or classic setting, these fans are sure to elevate any home environment.