How to Put Your Ceiling Fan Together

1.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.

PIN

HANGER

BALL

SETSCREW

DOWNROD

Figure 1

2.Unscrew the two setscrews (Figure 2) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the cle- vis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 2) could result in the fan falling.

DOWNROD

MOTOR

COUPLINGHAIRPIN CLIP

CLEVIS

PIN

SETSCREW (2)

Figure 2

3.Tighten the two setscrews (Figure 2) securely while pulling up on the downrod.

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

4.Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 3).

DOWNROD

CEILING

COVER

COUPLING

COVER

Figure 3

5.Reinstall the hanger ball (Figure 4) on the downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are proper- ly installed could result in the fan falling.

PIN

HANGER

BALL

DOWNROD

SETSCREW

Figure 4

6.The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

7.Mount blade flanges to fan blades using three M5 x 6mm slotted Phillips washer head screws (Figure 5).

IMPORTANT: THE SIDE OF THE FAN BLADE HAVING THE RIB LINE MUST BE FACING UPWARDS AS SHOWN IN FIGURE 5.

4

Image 4
Contents Devonshire Safety Instructions Date CodeTools Needed for Assembly Unpacking InstructionsHow to Put Your Ceiling Fan Together Electrical Requirements How to Hang Your Ceiling Fan How to Wire Your Ceiling FanUsing Your Ceiling Fan MaintenanceAccessories THREE-SPEEDTrouble Shooting Repair Parts ListingHOW to Order Repair Parts Trouble Probable Cause Suggested Remedy