How to Hang
Your Ceiling Fan
!WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).
CEILING
AT LEAST
7'
Figure 9
FLOOR
!WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support of 50 lbs. or less”.
!WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 50 lbs. or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
NOTE: CEILING COVER, |
| |
SUPPLY WIRES AND | OUTLET | |
FAN WIRES OMITTED | ||
BOX | ||
FOR CLARITY. | ||
|
| HANGER | |
| BRACKET | |
Figure 11 | HANGER BALL/ | |
DOWNROD ASSEMBLY | ||
|
!WARNING
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
How to Wire
Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
!WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
1.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 10.)
!WARNING
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
OUTLET
BOX
TWO SCREWS |
|
SUPPLIED WITH | HANGER |
OUTLET BOX | |
| BRACKET |
Figure 10 | TAB |
2.Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 11). Be sure the tab on the hanger bracket is seated in the groove on the hanger ball (Figure 10).
!WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied. (Figure 12.)
NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.
!WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage.
2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 12). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 12). After connections have been made, separate the white and green leads from the black and blue leads. Carefully turn the leads upward and push the green and white leads into one side of the outlet box. Then push the black and blue leads into the other side of the outlet box.
6