Emerson 350, 250 operation manual Transmitter Overview, General Description, Product Identification

Page 5

Section

 

2

Transmitter Overview

 

2.0 General Description

The LTM-Series are 2-wire electronic field instruments, suitable for installation in hazardous and non-hazardous locations. Testing and certification has been obtained from different agencies for installation in such areas. This instrument is designed to measure and transmit an analog and/or digital signal proportional to liquid level in a tank. The complete assembly includes an explosion-proof enclosure and attached sensor tube and a magnetic float. The LTM-Series are available in a variety of lengths and wetted materials to accommodate many different applications.

2.1 Product Identification

wwwwwwwwwwwwwwwwwwwwwww

ZZ/ZZ

S/N AAAA / OL BBBB

 

MODEL LTM- 350-G-XXXX

 

TAG YYYY

ISE-MAGTECH wwwwwwwwwwwwwwwwwwwwwww wwwwwwwwwwwwwwwwwwwwwww

Figure 1. Example label/name plate

The product can be identified by the stainless steel label that is located on the side of the transmitter enclosure/housing.

The label can be read as follows:

wwww= Any hazardous location area classification markings that the instrument is approved for.

ZZ/ZZ = Born on date; the2 digit month and 2 digit year the instrument was shipped to the customer.

AAAA= The specific serial number assigned by Magtech for complete traceability.

BBBB= The overall probe length of the instrument. Note: THIS IS NOT THE MEASURING RANGE.

XXXX= The measuring range of the instrument. The 0 and 100% (4/20mA) output range.

YYYY= The end user specified tag number (only when specified).

2.2 Transmitter Configurations

LTM-Series transmitters generally have two configurations:

1.Gage Mounted: Where the transmitter is mounted on the outside of a magnetic level gage and strategically located within a certain longitudinal distance from the transmitter sensor probe and a magnetic float is placed inside the level gage.

2.Standalone (or Direction Insertion Type): Where the transmitter has a magnetic float directly around the transmitter sensor probe and the probe is directly inserted into a tank/vessel.

In either configuration as the tank level changes, the float tracks the change and continuously activates the sensor probe. The electronics process the change in signal and output an analog and/or digital signal. This output is precisely the liquid level in the tank.

Magtech is always willing to explore unique applications that require their own distinctive configurations. Please consult the factory for guidance.

2

Image 5 Contents
Instructions Table of Contents LTM-350 has Hart Protocol Icon KeyWarranty WarrantyTransmitter Overview Transmitter ConfigurationsGeneral Description Product IdentificationStandalone Transmitter Gage Mounted TransmitterTransmitter with a Stilling-well Technology Theory of Operation Transmitter DescriptionDetailed Description Basic Transmitter Block Diagram Configuration options must be chosen at quoting stageGage Mount Installation InstallationStandalone Installation General Installation GuidelinesClamps do not have to meet Possible transmitter configurationsPage Insulation against extreme heat/cold When insulating gagesRecommended Loop Wiring Field WiringFollowing is the Hart Topology Area Classification Installation Safety Electronic Specifications Transmitter SpecificationsSensor Probe Specifications Hazardous Locations / General RatingsPushbutton Operation Menu Structure and FeaturesMain Screen scrolling Menu StructureFollowing is the LTM-250/350 LCD Menu Flowchart Menu Structure … Description Select PV Select AlarmChange Range LCD Menu examples G R n g e Select Lower Range Value LRVTrim Sensor DescriptionOffset M S n s r F sTest Loop Description Trim Digital-Analog-Converter DACExit LCD Menu examples I m D a C T L o o p I t ?MA Out Or % Range FeaturesScroll or Level or Intrface Following is a flow chart of the advanced menus Features Exclusive to the LTM-250/350 modelsFeatures Exclusive to the LTM-250/350 models Features Exclusive to the LTM-250/350 models Features Exclusive to the LTM-250/350 models Features Exclusive to the LTM-250/350 models Troubleshooting LTM TroubleshootingTransmitter Calibration CalibrationPhysical and water damage are not covered under warranty Power Supply TroubleshootingGeneral Troubleshooting Hart Protocol General Information LTM-350 has Hart ProtocolUSL Hart Protocol Menus and Flowchart …When Interf is PV, Interf is displayed