Emerson KF160OI01 owner manual Electrical Requirements, How to Assemble Your Ceiling Fan

Page 5

BP7283, High Country, KF160 7/31/06 10:54 AM Page 5

2. Slide the four switch levers on the code switch to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.

3. In the receiver (Figure 1), slide the four switch levers to the same positions as set in the transmitter. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.

4. Position the battery in the transmitter battery compartment and replace the battery cover.

CEILING FAN

PROCEDURES

Electrical Requirements

Your new ceiling fan will require a ground- ed electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws sup- plied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electri- cian if in doubt.

!WARNING

!WARNING

Turning off wall switch is not suffi- cient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

How to Assemble Your Ceiling Fan

1. Place the motor housing assembly on a flat surface with the top of the motor facing upwards. Place the upper glass over the motor housing assembly, aligning the slots in the upper glass with the mounting holes in the housing flange (Figure 2). Install three 8-32 x 15mm screws, flat washers, and rubber washers (supplied) to secure the assembly.

2. Place the motor housing/upper glass assembly onto the lower foam pad with the bottom of the motor facing you. The lower pad serves as a holder for the fan during the first stages of assembly.

8-32 x 15mm SCREW (3) FLAT WASHER (3)

RUBBER WASHER (3)

UPPER GLASS

MOTOR HOUSING

ASSEMBLY

To avoid possible fire or shock, fol- low all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the exist- ing light fixture.

Figure 2

3. Mount the fan blades to the blade flanges using three 10-24 x 9mm truss head screws and three fiber washers (supplied) (Figure 3).

5

Image 5
Contents High Country Additional Safety Instructions for Installation Safety InstructionsMaterials Installation of Battery General Preset Memory FeatureSetting Operating Frequency of Transmitter Receiver GeneralElectrical Requirements How to Assemble Your Ceiling FanRubber Washer Upper Glass Motor Housing Assembly Fiber Washer Adapter Plate Cutout for Flange Screw Access BladeTruss Head ScrewGrommet Decorative Scroll AssemblyHairpin Clip Setscrew Downrod Motor Coupling Clevis PIN PINCeiling Outlet BOX TWO Screws Supplied With How to Hang Your Ceiling FanTAB AT LeastHow to Wire Your Ceiling Fan Ceiling Cover WhiteLockwasher Knurled NUTAdapter Light Fitte Assembly Light Fitter Adapter White WireLight Fitter Socket Threaded Lower GlassOperating Your Ceiling Fan Installation Storage BracketLowremote Control Transmitter Important Care Instructions MaintenanceAccessoriesTrouble Probable Cause Suggested Remedy Trouble ShootingDescription KF160OI01 Repair Parts ListingLimited Warranty

KF160OI01 specifications

The Emerson KF160OI01 is a cutting-edge cooling solution designed for commercial and industrial applications, boasting a range of features that cater to efficiency, reliability, and ease of use. One of the standout aspects of this unit is its advanced refrigerant technology, which utilizes eco-friendly refrigerants to reduce environmental impact while maximizing cooling performance.

At its core, the KF160OI01 is engineered with a high-efficiency compressor that operates quietly and effectively, ensuring optimal performance while keeping energy costs low. This compressor is paired with a high-capacity condenser coil that enhances heat exchange capabilities, allowing the unit to cool large spaces quickly and effectively. This makes the KF160OI01 ideal for environments that require rapid temperature control, such as restaurants, warehouses, and manufacturing facilities.

Additionally, the Emerson KF160OI01 incorporates intelligent control systems that allow for precise temperature regulation. These smart controls enable users to set specific temperature thresholds and monitor energy consumption, enhancing overall operational efficiency. The inclusion of a digital display and user-friendly interface further simplifies the monitoring and adjustment of settings, making it easy for operators to maintain optimal conditions.

Durability is another significant characteristic of the KF160OI01. The unit is built with robust materials designed to withstand the rigors of continuous operation in demanding environments. This longevity is complemented by a built-in self-diagnostic feature that alerts users to any potential issues before they escalate, minimizing downtime and maintenance costs.

Furthermore, the KF160OI01 is designed with flexibility in mind. Its modular construction allows for easy integration into existing systems or replacement of older units. This adaptability ensures that it can meet a variety of installation requirements while providing consistent performance.

In summary, the Emerson KF160OI01 represents a pinnacle of innovation in commercial cooling technology. With its focus on energy efficiency, advanced controls, and durability, it stands out as a reliable solution for businesses looking to enhance their environmental comfort while minimizing costs and energy consumption. As industries increasingly prioritize sustainable practices, the KF160OI01 is poised to meet future demands, making it a wise investment for any commercial operation.