Emerson KF160OI01 Fiber Washer, Truss Head, Screw, PIN Blade Flange Hanger Ball Downrod

Page 6

BP7283, High Country, KF160 7/31/06 10:54 AM Page 6

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balanc- ing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

FIBER WASHER (3)

10-24 X 9mm

 

TRUSS HEAD

 

SCREW (3)

 

FAN BLADE

7. Carefully remove the fan motor housing assembly from the lower foam pad. Turn the housing assembly over and position it on the lower foam pad with the fan blades resting on the pad so that the top of the motor faces up.

8. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 5). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for rein- stallation in step 12.

PIN

BLADE FLANGE

HANGER

 

 

BALL

Figure 3

DOWNROD

 

SETSCREW

4. Remove and discard the three shipping

 

retainers securing the motor hub in the

Figure 5

motor housing.

NOTE: Take care not to scratch the fan housing when installing the blade assemblies.

5. Insert a 1/4-20 x 11mm pan head screw with lockwashers into each of the two recessed holes in one of the blade flanges.

6. Align two of the threaded holes in the motor with the two cutouts in the adapter plate (Figure 4). Position the blade flange on the motor hub so that the screws in the blade flange align with the two threaded holes in the motor hub. Tighten the two screws securely. Repeat this procedure for the remaining four blade assemblies.

ADAPTER

PLATE

CUTOUT FOR

FLANGE SCREW

ACCESS

BLADE

FLANGE

NOTE: If you have an eight-foot ceiling, you will have to use the 3-1/2” downrod (supplied) in order to maintain the nec- essary blade-to-floor clearance of seven feet.

9.Unscrew the two upper setscrews (Figure 6) until they clear the inside of the motor coupling. Then separate, untwist and unkink the four 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 6). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull up on the downrod to make sure the clevis pin is properly installed.

Figure 4

1/4-20 x 11mm PAN HEAD SCREW

6

 

WITH LOCKWASHER (2)

Image 6
Contents High Country Safety Instructions Additional Safety Instructions for InstallationMaterials Setting Operating Frequency of Transmitter Receiver General Preset Memory FeatureInstallation of Battery GeneralHow to Assemble Your Ceiling Fan Rubber Washer Upper Glass Motor Housing AssemblyElectrical Requirements Truss Head Adapter Plate Cutout for Flange Screw Access BladeFiber Washer ScrewHairpin Clip Setscrew Downrod Motor Coupling Clevis PIN Decorative Scroll AssemblyGrommet PINTAB How to Hang Your Ceiling FanCeiling Outlet BOX TWO Screws Supplied With AT LeastHow to Wire Your Ceiling Fan Lockwasher Knurled WhiteCeiling Cover NUTLight Fitter Socket Threaded Light Fitter Adapter White WireAdapter Light Fitte Assembly Lower GlassInstallation Storage Bracket Lowremote Control TransmitterOperating Your Ceiling Fan MaintenanceAccessories Important Care InstructionsTrouble Shooting Trouble Probable Cause Suggested RemedyRepair Parts Listing Description KF160OI01Limited Warranty

KF160OI01 specifications

The Emerson KF160OI01 is a cutting-edge cooling solution designed for commercial and industrial applications, boasting a range of features that cater to efficiency, reliability, and ease of use. One of the standout aspects of this unit is its advanced refrigerant technology, which utilizes eco-friendly refrigerants to reduce environmental impact while maximizing cooling performance.

At its core, the KF160OI01 is engineered with a high-efficiency compressor that operates quietly and effectively, ensuring optimal performance while keeping energy costs low. This compressor is paired with a high-capacity condenser coil that enhances heat exchange capabilities, allowing the unit to cool large spaces quickly and effectively. This makes the KF160OI01 ideal for environments that require rapid temperature control, such as restaurants, warehouses, and manufacturing facilities.

Additionally, the Emerson KF160OI01 incorporates intelligent control systems that allow for precise temperature regulation. These smart controls enable users to set specific temperature thresholds and monitor energy consumption, enhancing overall operational efficiency. The inclusion of a digital display and user-friendly interface further simplifies the monitoring and adjustment of settings, making it easy for operators to maintain optimal conditions.

Durability is another significant characteristic of the KF160OI01. The unit is built with robust materials designed to withstand the rigors of continuous operation in demanding environments. This longevity is complemented by a built-in self-diagnostic feature that alerts users to any potential issues before they escalate, minimizing downtime and maintenance costs.

Furthermore, the KF160OI01 is designed with flexibility in mind. Its modular construction allows for easy integration into existing systems or replacement of older units. This adaptability ensures that it can meet a variety of installation requirements while providing consistent performance.

In summary, the Emerson KF160OI01 represents a pinnacle of innovation in commercial cooling technology. With its focus on energy efficiency, advanced controls, and durability, it stands out as a reliable solution for businesses looking to enhance their environmental comfort while minimizing costs and energy consumption. As industries increasingly prioritize sustainable practices, the KF160OI01 is poised to meet future demands, making it a wise investment for any commercial operation.