TROUBLESHOOTING GUIDE (Continued)
PROBLEM | CAUSE | CORRECTION |
| ||||
|
|
|
|
|
|
| |
Compressor is not supplying | Compressor is not large enough for | Check the accessory air requirement. If it is higher | |||||
enough air to operate acces- | air requirement. | than the SCFM or pressure supplied by your air | |||||
sories. |
| compressor, you need a larger compressor. | |||||
|
|
| Restricted air intake filter. | Clean or replace air intake filter. Do not operate the | |||
|
|
|
| air compressor in any paint spray or drywall | |||
|
|
|
| sanding area. | |||
|
|
| Hole in hose. | Check and replace if required. | |||
|
|
| Check valve restricted. | Remove and clean, or replace. | |||
|
|
| Air leaks. | Tighten fittings. | |||
|
|
| |||||
Motor will not run or restart. | Present tank pressure exceeds | Motor will start automatically when tank pressure | |||||
|
|
| pressure switch | drops below | |||
|
|
| Fuse blown, circuit breaker tripped. | 1. Check fuse box for blown fuse and replace, if | |||
|
|
|
|
| necessary. Reset circuit breaker. Do not use a | ||
|
|
|
|
| fuse or circuit breaker with higher rating than | ||
|
|
|
|
| that specified for your particular branch circuit. | ||
|
|
|
| 2. | Check for proper fuse; only Time Delay fuses | ||
|
|
|
|
| are acceptable. | ||
|
|
|
| 3. Check for low voltage conditions and/or | |||
|
|
|
|
| proper extension cord. | ||
|
|
|
| 4. | Disconnect the other electrical appliances | ||
|
|
|
|
| from circuit or operate the compressor on its | ||
|
|
|
|
| own branch circuit. | ||
|
|
|
| 5. Check for loose electrical connections. | |||
|
|
| Motor overload protection switch has | Let motor cool off and overload switch will auto- | |||
|
|
| tripped. | matically reset. | |||
|
|
| Possible defective motor or | Return to Sears Service Center for inspection or | |||
|
|
| capactior. | replacement, if necessary. | |||
|
|
| Paint spray on internal motor parts. | Have compressor checked at Sears Service | |||
|
|
|
| Center. Do not operate the compressor in the paint | |||
|
|
|
| spray area. See flammable vapor warning. | |||
|
|
| Check valve stuck open, putting | Remove and clean, or replace the check valve. | |||
|
|
| pressure on head. |
|
|
|
|
|
|
| Pressure release valve on pressure | Bleed the line by pushing the lever on the pressure | |||
|
|
| switch has not unloaded head | switch to the "O" position; if the valve does not | |||
|
|
| pressure. | open, replace it. | |||
|
|
| Broken exhaust valve. | Inspect and replace if necessary. | |||
|
|
|
|
|
|
| |
| Regulator knob continuous air | Dirty or damaged regulator internal | Replace regulator. | ||||
| leak. Regulator will not shut | parts. |
|
|
|
| |
| off at air outlet. |
|
|
|
|
| |
|
|
|
|
|
|
|
|
11