Sears 919.72633 owner manual BREAK-IN Procedures, Location of the Air Compressor

Page 7

REMOVAL OF SHIPPING BOARDS AND INSTALLATION FOR STATIONARY (PERMANENTLY MOUNTED) UNITS

It may be necessary to brace or support one side of the outfit when removing the shipping boards because the air compressor will have a tendency to tip.

1.Remove all packaging such that only the compressor on the pallet remains. Remove and discard the (4) screws and washers that hold the compressor to the pallet.

2.This compressor is designed to be bolted directly to a level floor. Prior to installing, place the new washers which are supplied with the compressor, between the feet and floor such that the ring base at the bottom of the tank does not contact the floor. Tighten bolts 15-20 ft. lbs.

BREAK-IN PROCEDURES

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air filter must be kept clear of obstructions which could reduce air delivery of the air compressor. The air com- pressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of fresh intake and cooling air.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified technician.

Lubrication and Oil

This unit needs no lubrication or oiling.

Grounding Instructions

RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by provid- ing an escape wire for the electric current. This air compressor must be properly grounded.

This portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug.

Inspect the plug and cord before each use. Do not use if there are signs of damage.

If repairing or replacing cord or plug, the grounding wire must be kept separate from the current-carrying wires. Never connect the grounding wire to a flat blade plug ter- minal. The grounding wire has insulation with an outer sur- face that is green with or without yellow stripes.

If these grounding instructions are not completely under- stood, or if in doubt as to whether the compressor is prop- erly grounded, have the installation checked by a qualified electrician.

240 VOLT MODELS

7

Image 7
Contents MGP-726330 10/1/96 Model No 919.726330Table of Contents What to Look for What could Happen HOW to Prevent IT Safety Guidelines What could Happen HOW to Prevent IT Model No 919.726330 Specification ChartGeneral Information GlossaryDescription of Operation Tools Needed for AssemblyLocation of the Air Compressor BREAK-IN ProceduresVoltage and Circuit Protection Operating ProceduresCheck Valve Cleaning Replacement MaintenanceProblem Cause Correction Troubleshooting GuideTroubleshooting Guide Service Notes Service Notes Service and Repair Parts De modèle Tension et protection du circuit Table DES MatièresAvertissement Consignes DE SécuritéAir comprimé De modèle Nombre de cylindres Alésage Information GénéraleGlossaire Tableau DES SpécificationsOutils Nécessaires À L’ASSEMBLAGE Description DU FonctionnementLubrification et huile Installation ET RodageEmplacement du compresseur AssemblageTension et protection du circuit Mise EN MarcheDirectives de rodage Moteur Clapet de retenue Nettoyage et remplacementEntretien Soupape de sûreté InspectionGuide DE Dépannage Problème Cause SolutionGuide DE Dépannage suite Page Page DE Modèle Entretien Pour Commander DES Pièces DE Rechange