HANGER
BALL
SETSCREW
PIN
DOWNROD
!WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician in in doubt.
Figure 5
CEILING COVER
9.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 7.)
OUTLET
BOX
7.The fan comes with blue, black and white leads that are 80” long. Before installing the fan, measure up approximately 6 to
8.Your new ceiling fan will require a grounded 120 volts AC, 60 Hz, 15 amp electrical supply line. If your fan is to replace an existing ceiling light fix- ture, turn electricity off at the main fuse box at this
time and remove the existing light fixture.
!WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
!WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 6).
CEILING
TWO SCREWS |
|
SUPPLIED WITH |
|
OUTLET BOX | HANGER |
| BRACKET |
Figure 7 | TAB |
10.Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 8). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 7).
!WARNING
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
!WARNING
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
!WARNING
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
NOTE: CEILING COVER, |
| |
SUPPLY WIRES AND | OUTLET | |
FAN WIRES OMITTED | ||
BOX | ||
FOR CLARITY. | ||
|
AT LEAST
7'
Figure 6 | FLOOR |
!WARNING
The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.
Figure 8
5
HANGER
BRACKET
HANGER BALL/ DOWNROD ASSEMBLY