Sound Performance Lab 2053 manual Operation, AD Mode Switch, Error LEDs

Page 10

Operation

AD MODE Switch

The AD MODE switch is used to set the desired bit mode and sample rate.The follo- wing list explains the respective switch positions:

16 Bit Mode

E = AES

Ext. Synchronization to AES clock

D = DA

Synchronization zum D/A converter

C = WC

Ext. Synchronization to word clock

B = 48

Int. Synchronization to 48 kHz

A = 44,1

Int. Synchronization to 44,1 kHz

9

= 96

Int. Synchronization to 96 kHz

8

= 88,2

Int. Synchronization to 88,2 kHz

24 Bit Mode

0

= 88,2

Int. Synchronization to 88,2 kHz

1

= 96

Int. Synchronization to 96 kHz

2

= 44,1

Int. Synchronization to 44,1 kHz

3

= 48

Int. Synchronization to 48 kHz

4

= WC

Ext. Synchronization to word clock

5

= DA

Synchronization to D/A converter

6

= AES

Ext. Synchronization to AES clock

Error LEDs

The Error-LEDs indicate faulty audio signals at the S/P- DIF input or faulty sync signals at the WC/AES SYNC INPUT (=S/P-DIF output). In this case the respective signal is muted.

10

24/96 AD-DA Converter 2053

Image 10
Contents Manual 24/96 AD-DA Converter Manual Contents Security Advices Product DescriptionMounting Steps 1 Steps 3 Connections Analog XLR OutputsOperation Digital I/OsError LEDs AD Mode SwitchOperation External Synchronization Channel ONE Using both channels of the converter Channel ONE Using both convertersApplications Analog processing of a digital signal Monitoring in 24Bit/96kHzExample 1 Processing a samplers signal Example 2 Recording on a DAT recorderSpecifications ConverterBlock Diagram Measurements THD&N above input level THD&N @ 1 kHz FFTMeasurements Warranty Sound Performance Lab Sohlweg Niederkruechten Germany