Sound Performance Lab 2053 manual External Synchronization

Page 11

Operation

External Synchronization

External Synchronization (Connection via W/C-AES SYNC INPUT) is required when several signals must be brought together within a chain of digital units, e.g. when connecting several digital units at one console. Since the sample frequencies are never exactly iden- tical, not synchronized sample rates inevitably have different timings - samples are ignored or read twice, usually audible als cracking.

By supplying all signal sources with a common frequency, all signals are synchronized and sample faults are avoided.

The common frequency can either be transmitted via unbalanced coaxial wiring using a BNC/CINCH adapter as Word/House Clock or as AES data if connected as shown in the graphic below. In both cases the WC/AES SYNC INPUT is to be used.

1

2

3

AES XLR Connector

1 = GND, 2 = Signal,

3 = Signal to GND (3 to 1)

1

2

Cinch

1 = Sleeve

2 = Tip

24/96 AD-DA Converter 2053

11

Image 11
Contents Manual 24/96 AD-DA Converter Manual Contents Product Description Security AdvicesMounting Steps 1 Steps 3 Analog XLR Outputs ConnectionsDigital I/Os OperationOperation AD Mode SwitchError LEDs External Synchronization Applications Channel ONE Using both convertersChannel ONE Using both channels of the converter Monitoring in 24Bit/96kHz Analog processing of a digital signalExample 2 Recording on a DAT recorder Example 1 Processing a samplers signalConverter SpecificationsBlock Diagram THD&N above input level THD&N @ 1 kHz FFT MeasurementsMeasurements Warranty Sound Performance Lab Sohlweg Niederkruechten Germany