A drive system requires energy for acceleration or constant movement that must be supplied to the system.

During deceleration, a motor acts as a generator. A considerable por- tion of the kinetic energy is re-generated as electrical energy.

Since electrical energy can only be stored to a limited extent in a sin- gle drive, a drive uses a braking resistor to transform the excess energy into thermal energy.

Use of electrical energy If an application operates with multiple drive systems, it may be useful to employ a common DC bus. By sharing a common DC bus, the energy regenerated by one drive can be supplied to another drive.

Common DC bus Whether or not a common DC bus makes sense depends on the acceleration and deceleration cycles of the drive systems.

A common DC bus is useful, for example, if one drive systems accel- erates while another drive system decelerates.

If the drive systems accelerate and decelerate at the same time, a common DC bus does not make sense.

MNA01M001EN, V1.01, 08.2014

Common DC bus

13

Image 13
Contents LXM32 LXM32 Table of contents Accessories and spare parts Hazard categories Safety InformationIntended use Qualification of personnelBasic information Loss of Control Standards and terminology DC bus voltage measurementLXM32 About the book LXM32 Introduction Permissible device types for common DC bus Firmware version Technical DataDC bus data LXM32 ∙ U45M2 U90M2 D18M2 D30M2 Braking resistorParameter DCbuscompat VW3A760 1Rxx 2Rxx 3Rxx 4Rxx 5Rxx 6Rxx 7Rxx External braking resistors accessoriesCables for the DC bus Engineering Energy balance basics Energy balanceRating DC bus connection Electromagnetic compatibility EMCFuses DC bus connection of single-phase drivesSee .2 DC fuses for fuses for the DC bus Single mains fuse for three-phase drives DC bus connection of three-phase drivesMultiple mains fuses for three-phase drives Supply via the DC bus Supply via the DC bus by a drive LXM32 Rating the braking resistor Braking resistorsPmax Rating information Selecting an external braking resistor Mains reactor L2 L1 PC/- PA/+ Mains filter Mains reactor and external mains filter LXM32 Installation Assembling cables Specifications for drives with mains supplyPart Length in mm inches LXM32∙ D85, C10 Drives with connectors Wiring the DC busNector Properties of the connection termi- nals CN9 Drives with terminalsDC bus connection, example with connector Connecting the DC busVerifying installation LXM32 Commissioning DC bus connection LXM32 to LXM32 Commissioning procedureMONMainsVolt LXM32 Setting the braking resistor parameters DC bus accessories Accessories and spare partsDC fuses External braking resistors Units and conversion tables GlossaryRotation TemperatureTorque Moment of inertiaTerms and Abbreviations LXM32 Table of figures LXM32 EMC IndexLXM32

MNA01M001EN specifications

The Schneider Electric MNA01M001EN is a highly advanced solution designed to optimize energy management and enhance operational efficiency in various applications. As a crucial component in Schneider Electric's portfolio of energy management systems, the MNA01M001EN stands out due to its innovative features and robust technologies.

One of the main features of the MNA01M001EN is its seamless integration capabilities. The device supports interfaces such as Modbus, which allows it to connect to a variety of energy monitoring devices and systems. This interoperability ensures that users can easily connect their existing infrastructure without needing significant alterations, streamlining the energy monitoring process.

Another notable characteristic of the MNA01M001EN is its real-time monitoring capabilities. The device provides instant access to critical data, which enables users to make informed decisions regarding energy consumption. By continuously tracking energy usage, the MNA01M001EN facilitates timely interventions that can lead to substantial energy savings and improved operational performance.

In terms of technology, the MNA01M001EN employs advanced analytics to interpret energy data effectively. This feature empowers businesses to identify patterns in energy consumption, recognize inefficiencies, and make strategic adjustments. The use of predictive analytics also enables proactive maintenance strategies, minimizing potential downtime and optimizing resource allocation.

The MNA01M001EN is designed with user-friendliness in mind. Its intuitive interface simplifies navigation, making it accessible to a wide range of users, from energy managers to facility operators. Moreover, the device is equipped with customizable dashboards that allow users to visualize important metrics in ways that suit their specific needs and preferences.

In addition, the MNA01M001EN is built with sustainability as a core principle. By promoting energy efficiency, the device not only helps organizations reduce their carbon footprint but also leads to significant cost savings in energy bills. As organizations continue to prioritize sustainability, products like the MNA01M001EN play an essential role in driving those efforts forward.

Furthermore, its compact design allows for easy installation in various environments, making it a versatile choice for different types of facilities, whether industrial, commercial, or residential. The robust build quality ensures durability, allowing the device to withstand demanding conditions.

In summary, the Schneider Electric MNA01M001EN is an essential tool in modern energy management. With its integration capabilities, real-time monitoring, advanced analytics, user-friendly design, and commitment to sustainability, it represents a powerful solution for organizations looking to optimize their energy usage and enhance their operational efficiency.