LXM32 | 5 Commissioning |
5.1.2Supply via the DC bus
Commissioning steps:
▶Verify proper installation of the drives and the connections for the common DC bus, see chapter "4.3 Verifying installation", page 49.
▶Switch on the controller supply for all devices.
▶LXM32: Set the parameter MON_MainsVolt to
Parameters | Value |
MON_MainsVolt |
▶LXM32: Set the parameters for the braking resistors of LXM32 drives, see chapter
"5.2 LXM32: Setting the braking resistor parameters".
▶Commission the drives, see the descriptions in the manuals for the individual products.
MNA01M001EN, V1.01, 08.2014
Common DC bus | 53 |