SECTION 2 – INSTALLATION
2-1. Specifications
| Amperes Input at Rated Load |
|
|
|
|
|
| Maximum | |||
|
|
|
|
|
| Rated | Open- | ||||
|
| Output 60 Hz |
|
|
| Type of | Plasma | Rated | |||
Model |
|
|
|
| Cutting | Circuit | |||||
|
|
|
|
|
| Output | Gas | Output | |||
| 200 V | 230 V | 460 V | 575 V | KVA | KW | Capacity | Voltage | |||
|
|
|
| ||||||||
|
|
|
|
| DC | ||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Single- | 42.30 | 36.80 | 18.40 | 8.49 | 6.55 | Direct |
| 50 A @ |
|
| |
Phase | (3.40*) | (2.95*) | (1.50*) | (0.68*) | (0.20*) | Current, | Air Or | 0.7 in |
| ||
| 110 Volts | 280 | |||||||||
|
|
|
|
|
|
| Straight | Nitrogen | (18 mm) | ||
|
| 18.40 | 9.20 | 7.40 | 7.32 | 6.60 | DC, 60% | ||||
Polarity | Only | At 10 IPM |
| ||||||||
Duty Cycle |
| ||||||||||
(2.13*) | (1.07*) | (0.85*) | (0.85*) | (0.32*) | (DCEN) |
|
|
| |||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
*While idling
2-2. Dimensions And Weight
C
B
A
Ref. 801
Dimensions
A
B
C | 21 in (533 mm) |
Weight
*Without Torch
2-3. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min- utes that unit can cut at rated load without overheating.
If unit overheats, thermostat(s)
60% Duty Cycleopens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before cutting.
Y Exceeding duty cycle can damage unit and void war- ranty.
6 Minutes Cutting | 4 Minutes Resting |
Overheating
0 | A |
| 15 |
| OR |
Minutes | Reduce Duty Cycle |
duty1 4/95