4-2. Trouble Lights

Difficulty establishing pilot arc may indicate consumables need to be cleaned or replaced.

1

2

3

1 Pressure Light

Lights if gas/air pressure is below 40 PSI (276 kPa).

Turn power Off, and check for prop- er gas/air pressure (see Section 3-2).

2 Cup Light

Lights if shield cup is loose.

Turn power Off, and check shield cup connection (see torch Owner’s Manual). Power must be reset whenever the cup shutdown is activated.

Check shield cup shutdown system once a week (see Section 4-3).

3 Temperature Light

Lights if power source overheats (see Section 2-3).

4-3. Checking Shield Cup Shutdown System

. Power must be reset whenever the cup shutdown

system is activated. Always turn Off power when changing or checking consumables.

1

1 Torch Shield Cup

Turn Power On and loosen shield cup. If shutdown system works properly, Ready light goes off and Cup light comes on. If not, immedi- ately turn Off power and have Fac- tory Authorized Service Agent check safety control board PC1 op- eration.

If system works properly, retighten cup and reset power.

Ref. 801 300-A

OM-279 Page 18

Image 22
Contents Processes OM-279Description From Hobart to You Table of Contents Page Plasma Arc Cutting Hazards Symbol UsageMarks a special safety message Cutting can cause fire or explosionARC Rays can burn eyes and skin Exploding Parts can injureFlying Sparks can cause injury Noise can damage hearingFlying Metal can injure eyes HOT Parts can cause severe burnsMoving Parts can cause injury Overuse can cause OverheatingEMF Information Principal Safety StandardsAbout Pacemakers UNE DÉ Charge É Lectrique peut entraîner la mort Signification des symbolesLE Coupage pré sente un risque de feu ou d’explosion Identifie un message de sé curité particulierLES Fumé ES ET LES GAZ peuvent ê tre dangereux Risque de blessure en casLE Bruit peut endommager l’ouïe LE Plasma D’ARC peut entraîner des blessuresDES Organes Mobiles peuvent provoquer des blessures LES Bouteilles peuvent exploser si elles sont endommagé esDES Pieces Chaudes peuvent pro- voquer des brû lures graves DES Particules Volantes peuvent blesser les yeuxInformation sur les champs é lectromagné tiques Principales normes de sé curitéConsignes relatives aux stimulateurs cardiaques Dimensions And Weight InstallationSpecifications Duty Cycle And OverheatingSelecting a Location Special installation may beCutting Speed Movement Location And AirflowConnecting Gas/Air Supply Electrical Service GuidePlacing Jumper Links Always connect Connecting Input PowerThree-Phase System Grounding conductor firstOperation Front Panel ControlsSetting Gas/Air Pressure Set pressure to 70 PSI 483 kPaExample Of Cutting Operation Sequence Of OperationTrigger is pressed Maintenance & Troubleshooting MonthsTrouble Lights Checking Shield Cup Shutdown SystemTroubleshooting Running slowlyFan motor FM does not run Power light Electrical Diagrams Circuit Diagram For 200/230/460 Volt ModelsCircuit Diagram For 230/460/575 Volt Models OM-279 Parts List Main AssemblyDia Part Mkgs Description Quantity Consumable Parts For ICE-50C Service SupportContact your Distributor for Hobart Welding Products