4-2. Trouble Lights
Difficulty establishing pilot arc may indicate consumables need to be cleaned or replaced.
1
2
3
1 Pressure Light
Lights if gas/air pressure is below 40 PSI (276 kPa).
Turn power Off, and check for prop- er gas/air pressure (see Section
2 Cup Light
Lights if shield cup is loose.
Turn power Off, and check shield cup connection (see torch Owner’s Manual). Power must be reset whenever the cup shutdown is activated.
Check shield cup shutdown system once a week (see Section
3 Temperature Light
Lights if power source overheats (see Section
4-3. Checking Shield Cup Shutdown System
. Power must be reset whenever the cup shutdown
system is activated. Always turn Off power when changing or checking consumables.
1
1 Torch Shield Cup
Turn Power On and loosen shield cup. If shutdown system works properly, Ready light goes off and Cup light comes on. If not, immedi- ately turn Off power and have Fac- tory Authorized Service Agent check safety control board PC1 op- eration.
If system works properly, retighten cup and reset power.
Ref. 801