Hobart 750 manual Consumable Parts For ICE-50C

Page 30

Item

Dia.

Part

 

 

No.

Mkgs.

No.

Description

Quantity

 

 

 

Figure 6-1. Main Assembly (Continued)

 

 

 

 

 

 

. . . 45 .

. . . . . . . . . . . .

. . . . . . . . . . .

PANEL, front (consisting of)

. . . . 1

. . . . . . .

. . . . . . . . . . .

+206 446 . . .

. PANEL, front

. . . . 1

. . . . . . .

. . . . . . . . . . . .

. . . . . . . . . . . .

. NAMEPLATE, (order by model and serial number)

. . . . 1

. . . . . . .

. . . . . . . . . . . .

204 326 . . .

. CONSUMABLE STORAGE BOX w/DOOR

. . . . 1

. . . . . . .

. . . . . . . . . . . .

089 899 . . .

. LATCH, slide

. . . . 1

. . . . . . .

. . . . . . . . . . . .

206 303 . . .

. LABEL, ICE-50C consumables

. . . . 1

. . . . . . .

. . . PC1 . . .

192 790 . . .

. CIRCUIT CARD ASSEMBLY, safety control

. . . . 1

. . . . . . .

. . . . . . . . . . . .

184 544 . . .

. LINER, polycarbonate lens

. . . . 1

. . . . . . .

. . . . . . . . . . . .

176 478 . . .

. STAND-OFF, support PC card

. . . . 4

. . . . . . .

. . . . S2 . . . .

155 013 . . .

. SWITCH, rocker SPST 10A 250VDC

. . . . 1

. . . . . . .

. . . . . . . . . . . .

174 991 . . .

. KNOB, pointer

. . . . 1

. . . . . . .

. . . . S1 . . . .

128 756 . . .

. SWITCH, toggle 3PST 40A 600VAC scr

. . . . 1

. . . . . . .

. . . . . . . . . . . .

181 708 . . .

. GASKET, switch

. . . . 1

. . . . . . .

. . C1,2,3 . .

129 954 . . .

. CAPACITOR, (3 phase model)

. . . . 3

. . . . . . .

. . . C1,2 . . .

129 954 . . .

. CAPACITOR, (1 phase model)

. . . . 2

. . . . . . .

. . . . . . . . . . . .

178 739 . . .

. FITTING, plstc Qdisc straight fem 1/8NPT

. . . . 1

. . . . . . .

. . . . . . . . . . . .

179 536 . . .

. TUBING, pneumatic .250 OD x .170 ID x 10.00

. . . . 1

. . . . . . .

. . . . . . . . . . . .

179 537 . . .

. TUBING, pneumatic .250 OD x .170 ID x 17.00

. . . . 1

. . . . . . .

. . . . . . . . . . . .

190 585 . . .

. GAUGE, pressure air 0–160psi w/fittings

. . . . 1

. . . . . . .

. . . . . . . . . . . .

188 962 . . .

. HOSE, PVC .312 ID x .437 OD x 29.500

. . . . 1

. . . . . . .

. . . . . . . . . . . .

168 343 . . .

. HINGE, cont polyolefin 2.00 L w/.125H

. . . . 2

. . . . . . .

. . . . . . . . . . . .

199 997 . . .

. COVER, safety control board

. . . . 1

. . . 46 .

. . . . . . . . . . . .

136 156 . . .

. LABEL, general precautionary

. . . . 1

. . . 47 .

. . . Work . . .

199 020 . .

CABLE, work 20ft No. 8 w/strain relief and term

. . . . 1

. . . 48 .

. . . Work . . .

199 995 . .

CONTACT TIP, work clamp

. . . . 2

. . . . . .

PLG22,27,37

164 900 . .

CONNECTOR & SOCKETS

. . . . 3

. . . . . . .

. . PLG10 . .

164 899 . .

CONNECTOR & SOCKETS

. . . . 1

. . . . . . .

. . PLG5 . . .

167 640 . .

CONNECTOR & SOCKETS

. . . . 1

. . . . . . .

. PLG24,34 .

168 071 . .

CONNECTOR & SOCKETS

. . . . 2

. . . . . . .

. PLG26,36 .

176 121 . .

CONNECTOR, rect univ 084

. . . . 2

. . . . . . .

. . PLG12 . .

153 501 . .

CONNECTOR & SOCKETS

. . . . 1

. . . . . . .

. PLG21,31 .

158 720 . .

CONNECTOR & SOCKETS

. . . . 2

. . . . . . .

. . PLG11 . .

169 240 . .

CONNECTOR & SOCKETS

. . . . 1

. . . . . . .

. . PLG2,8 . .

170 888 . .

CONNECTOR & SOCKETS

. . . . 1

. . . . . . .

. . PLG25 . .

131 056 . .

CONNECTOR & SOCKETS

. . . . 1

. . . 49 .

. . . . . . . . . . . .

. . . . . . . . . . .

ICE-50C, (order separately)

 

. . . . . . .

. . . . . . . . . . . .

176 824 . .

ICE-50C, 25ft

. . . . 1

. . . . . . .

. . . . . . . . . . . .

176 826 . .

ICE-50C, 50ft

. . . . 1

. . . . . . .

. . . . . . . . . . . .

176 828 . .

ICE-50CM, 50ft machine mounted

. . . . 1

. . . . . . .

. . . . . . . . . . . .

180 605 . .

PENDANT CONTROL, (recommended for use w/ICE-50CM)

. . . . 1

. . . 50 .

. . . . . . . . . . . .

192 893 . .

DISCONNECT, quick ICE-50

. . . . 1

. . . 51 .

. . . . . . . . . . . .

201 817 . .

FLANGE, receptacle

. . . . 1

. . . 52 .

. . . . . . . . . . . .

204 239 . .

SPACER

. . . . 1

+When ordering a component originally displaying a precautionary label, the label should also be ordered.

To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.

Drag Shield

Retaining Cup

Tip

Electrode

Swirl Ring

O–Ring

192 053

192 050

177 890

192 047

177 886

169 232

Shield

 

 

 

Standard

 

 

 

 

Cutting

Apply silicone

192 058

Machine

 

 

 

Cutting

 

 

 

grease (169 231)

 

 

 

 

 

before installing.

Deflector

Retaining Cup

Tip

Electrode

 

 

177 888

192 050

177 876

192 048

Extended

 

 

 

 

 

 

 

 

 

 

Cutting

1/8” (3mm)

Shield

Retaining Cup

Tip

Electrode

 

stand–off

 

recommended

192 203

192 050

177 878

192 047

 

 

 

Gouging

Ref. 206 303

Figure 6-2. Consumable Parts For ICE-50C

OM-279 Page 26

Image 30
Contents OM-279 ProcessesDescription From Hobart to You Table of Contents Page Plasma Arc Cutting Hazards Symbol UsageMarks a special safety message Cutting can cause fire or explosionARC Rays can burn eyes and skin Exploding Parts can injureFlying Sparks can cause injury Noise can damage hearingFlying Metal can injure eyes HOT Parts can cause severe burnsMoving Parts can cause injury Overuse can cause OverheatingPrincipal Safety Standards EMF InformationAbout Pacemakers UNE DÉ Charge É Lectrique peut entraîner la mort Signification des symbolesLE Coupage pré sente un risque de feu ou d’explosion Identifie un message de sé curité particulierLES Fumé ES ET LES GAZ peuvent ê tre dangereux Risque de blessure en casLE Bruit peut endommager l’ouïe LE Plasma D’ARC peut entraîner des blessuresDES Organes Mobiles peuvent provoquer des blessures LES Bouteilles peuvent exploser si elles sont endommagé esDES Pieces Chaudes peuvent pro- voquer des brû lures graves DES Particules Volantes peuvent blesser les yeuxPrincipales normes de sé curité Information sur les champs é lectromagné tiquesConsignes relatives aux stimulateurs cardiaques Dimensions And Weight InstallationSpecifications Duty Cycle And OverheatingSelecting a Location Special installation may beCutting Speed Movement Location And AirflowConnecting Gas/Air Supply Electrical Service GuidePlacing Jumper Links Always connect Connecting Input PowerThree-Phase System Grounding conductor firstOperation Front Panel ControlsSetting Gas/Air Pressure Set pressure to 70 PSI 483 kPaSequence Of Operation Example Of Cutting OperationTrigger is pressed Maintenance & Troubleshooting MonthsTrouble Lights Checking Shield Cup Shutdown SystemTroubleshooting Running slowlyFan motor FM does not run Power light Electrical Diagrams Circuit Diagram For 200/230/460 Volt ModelsCircuit Diagram For 230/460/575 Volt Models OM-279 Parts List Main AssemblyDia Part Mkgs Description Quantity Consumable Parts For ICE-50C Service SupportContact your Distributor for Hobart Welding Products