Mamiya Econotig manual Example of Front Panel Amperage Control, Example of Remote Amperage Control

Page 20

6-2. Example of Front Panel Amperage Control

 

 

 

In Example:

 

 

 

Range = DC

Select weld process.

Select range and polarity.

Select percentage.

Percentage of Range = 50%

Weld Amperage = 33 A DC

6-3. Example of Remote Amperage Control

Select weld process.

 

Select range and polarity.

 

Select percentage.

 

 

 

 

 

GTAW Welding Amperage Range

or

AC Low

AC High

DC

20-50 A

60-165 A

30-165 A

 

 

In Example:

 

 

Range = DCEN

 

 

Percentage of Range = 50%

 

 

Remote weld amperage = 30−98 A DC

Connect remote control.

(50% of 30−165 A DC)

 

OM-303 Page 16

Image 20
Contents Processes DescriptionFrom Miller to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Signification des symboles − Consignes DE Sécurité − À Lire Avant UtilisationLES Décharges Électriques peuvent être mortelles LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut causer un incen- die ou une explosion LES Particules Projetées peu- vent blesser les yeuxLES Pièces Chaudes peuvent cau- ser des brûlures graves LE Bruit peut affecter l’ouïeRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut Faire LES Pièces Mobiles peuvent cau- ser des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sécuritéInformation sur les champs électromagnétiques General Precautionary Label − DefinitionsIncluded with Your Unit Symbols And Definitions− Introduction Specifications Duty Cycle ChartVolt-Ampere Curves Hertz Models− Installation Turn Off power before mak- ing connectionsSelecting a Location Typical Stick ConnectionsTurn Off power before mak Ing connections Typical TIG ConnectionsElectrical Service Guide Connecting Input Power− Operation ControlsExample of Front Panel Amperage Control Example of Remote Amperage ControlGtaw Welding Amperage Range AC Low AC HighProcess and Material Thickness Guide Label Troubleshooting − Maintenance and TroubleshootingRoutine Maintenance − Electrical Diagrams Circuit DiagramIncorrect Installation − High FrequencyWelding Processes Requiring High Frequency Weld ZoneMetal Building Requirements Correct InstallationMetal Building − Parts List Main AssemblyDia Part Description Quantity Mkgs Figure -1. Main Assembly Page Page Service SupportOwner’s Record Miller Electric Mfg. Co