Specifications |
|
|
|
|
|
|
|
|
|
| ||
A. 60 Hertz Models |
|
|
|
|
|
|
|
|
|
|
| |
Rated Output at 20% Duty | Welding Amperage Range | Max. | Rated Output | KVA | KW | Dimensions | Net | |||||
Cycle |
| AC High | AC Low | DC | OCV |
|
|
|
|
| Weight | |
TIG: | 150 A at 15 VDC |
|
|
|
|
|
|
|
|
|
|
|
(GTAW) | 150 A at 15 VAC | 50−165 | 20−50 | 30−160 |
|
| 200 V−60 A (3.6)* | 12.0 | 5.4 | H: 18 in (457 mm) | 140 lb | |
|
|
|
|
| 78 |
| 230V−52 A (3.0)* | (0.64)* | (0.3)* W: 13 in (330 mm) | (64 kg) | ||
Stick: | 130 A at 25 VDC |
|
|
|
|
|
| |||||
|
|
|
|
| 460 V−33 A (1.5)* |
|
| D: 251/ in (648 mm) |
| |||
|
|
|
|
|
|
|
|
|
| |||
(SMAW) | 150 A at 25 VAC | 35−165 | 20−50 | 25−130 |
|
|
|
|
| 2 |
|
|
|
|
|
|
|
|
|
| |||||
* () While idling. |
|
|
|
|
|
|
|
|
|
|
| |
B. 50 Hertz Models |
|
|
|
|
|
|
|
|
|
|
| |
Rated Output at 20% Duty | Welding Amperage Range | Max. | Rated Output | KVA | KW | Dimensions | Net | |||||
Cycle |
| AC High | AC Low | DC | OCV |
|
|
|
|
| Weight | |
TIG: | 150 A at 15 VDC | 50−165 | 20−50 | 30−160 |
|
|
|
|
|
|
|
|
(GTAW) | 150 A at 15 VAC |
|
|
|
|
| 380 V−39 A (2.0)* | 14.8 | 6.7 | H: 18 in (457 mm) | 140 lb | |
Stick: | 130 A at 25 VDC | 35−165 | 20−50 | 25−130 | 78 |
| 415 V−36 A (1.5)* | (0.64)* | (0.3)* W: 13 in (330 mm) | (64 kg) | ||
|
|
| ||||||||||
(SMAW) | 150 A at 25 VAC |
|
|
|
|
|
|
|
| D: 251/2 in (648 mm) |
| |
* () While idling. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Duty cycle is percentage of 10 | ||
|
|
|
|
|
|
|
|
|
| minutes that unit can weld at rated | ||
|
|
|
|
|
|
|
|
|
| load without overheating. |
| |
|
|
|
|
|
|
|
|
|
| Y Exceeding duty | cycle | can |
|
|
|
|
|
|
|
|
|
| damage unit | and | void |
|
|
|
|
|
|
|
|
|
| warranty. |
|
|
|
|
|
| GTAW: | 20% Duty Cycle at 150 A AC/DC |
|
|
|
| |||
|
|
|
| SMAW: | 20% Duty Cycle at 130 A DC, or |
|
|
|
| |||
|
|
|
|
|
| 150 A AC |
|
|
|
|
|
2 Minutes | 8 Minutes |
Welding | Resting |
4-4. Volt-Ampere Curves
ssb1.1 10/91 −