Mamiya Econotig manual Operation, Controls

Page 19

SECTION 6 − OPERATION

6-1. Controls

6

1

8

7

2

3

5

4

Ref. ST-155 790-F

1 Weld Process Switch

Use switch to select weld process.

In Stick position (down), weld output goes On and Off with Power switch.

In GTAW (TIG) position (up), remote control device turns on and adjusts weld output of unit as limited by Amperage control. Built-in arc starter comes on when needed to start or stabi- lize welding arc. No adjustments needed for arc starter.

2Pilot Light

3Power Switch

Use switch to turn unit, fan, and pilot light On and Off.

4 Amperage Control

For Stick (SMAW), use control to adjust amper- age within range selected by the Range/Polar- ity Switch.

5 Stick (SMAW) Table

Use table to find approximate Stick amperage output at Amperage control setting.

See Section 6-2for example of front panel am- perage control.

For remote amperage control used when TIG (GTAW) welding, front panel Amperage control setting is the maximum amperage percentage available at the remote control device.

See Section 6-3for example of remote amper- age control.

6 Range/Polarity Switch

Use switch to select range and polarity of weld output.

For Direct Current Electrode Negative (DCEN), use Electrode Negative position.

For Direct Current Electrode Positive (DCEP), use Electrode Positive position.

For alternating current (AC), use range needed for welding application − AC Low or AC High position − see Warning.

See Section 6-4to find suggested type of weld output for application.

7 High Temperature Shutdown Light

Lights when unit overheats and shuts down (see Section 7-2).

8 Output On (Contactor) Light

Lights when output (contactor) and unit power are on.

OM-303 Page 15

Image 19
Contents Description ProcessesFrom Miller to You Table of Contents Page Electric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal can injure eyesCalifornia Proposition 65 Warnings EMF Information Principal Safety StandardsAbout Pacemakers LES Fumées ET LES GAZ peuvent être dangereux Signification des symboles− Consignes DE Sécurité − À Lire Avant Utilisation LES Décharges Électriques peuvent être mortellesLE Bruit peut affecter l’ouïe LE Soudage peut causer un incen- die ou une explosionLES Particules Projetées peu- vent blesser les yeux LES Pièces Chaudes peuvent cau- ser des brûlures gravesLES Pièces Mobiles peuvent cau- ser des blessures Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peut FaireInformation sur les champs électromagnétiques Principales normes de sécuritéConsignes relatives aux stimulateurs cardiaques − Definitions General Precautionary Label− Introduction Symbols And DefinitionsIncluded with Your Unit Hertz Models SpecificationsDuty Cycle Chart Volt-Ampere CurvesTypical Stick Connections − InstallationTurn Off power before mak- ing connections Selecting a LocationTypical TIG Connections Turn Off power before mak Ing connectionsConnecting Input Power Electrical Service GuideControls − OperationAC Low AC High Example of Front Panel Amperage ControlExample of Remote Amperage Control Gtaw Welding Amperage RangeProcess and Material Thickness Guide Label Routine Maintenance − Maintenance and TroubleshootingTroubleshooting Circuit Diagram − Electrical DiagramsWeld Zone Incorrect Installation− High Frequency Welding Processes Requiring High FrequencyMetal Building Correct InstallationMetal Building Requirements Main Assembly − Parts ListDia Part Description Quantity Mkgs Figure -1. Main Assembly Page Page Support ServiceMiller Electric Mfg. Co Owner’s Record