BP7404 Tilo 12/16/09 4:06 PM Page 8
Installing the Ceiling
Cover on the
Fan Motor Housing
(For Close-to-the-Ceiling Mounting)
NOTE: The decorative lower cover, coupler cover and hanger ball assembly are not needed for
1. Remove and retain three screws from the top of the motor housing (Figure 9).
2. Position the rubber gasket (supplied in parts bag) on the motor housing (small holes in gasket cenered over the screw holes in the housing) Figure 9.
REMOVE AND RETAIN
3 SCREWS (every other one)
RUBBER
GASKET
MOTOR
HOUSING
Figure 9
3. Position the ceiling cover onto the top of the motor housing and reattach the three screws previously removed (Figure 10).
CEILING
COVER
SCREW (3)
RUBBER
GASKET
Installation of
Hanger Bracket
! WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 11).
CEILING
AT
LEAST
7'
FLOOR
Figure 11
! WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
1. Position the hanger bracket on the outlet box so that the
NOTE: The four hanger bracket screws and lockwashers are included in the parts bag for this fan. Must be installed for
Figure 10
LOOSEN TWO |
| |
SCREWS (SUPPLIED |
| |
WITH OUTLET BOX) | OUTLET | |
| BOX | |
| ||
| SLIDE THE HANGER | |
| BRACKET ONTO | |
| THE OUTLET BOX | |
| SCREWS, THROUGH | |
| THE | |
| HANGER | |
Figure 12 | BRACKET | |
UL Model No.: CF130 | ||
8 |