B
C
Fig. 28
splitter (P) is aligned with the saw blade (B). Using a square (C) Figs. 28 and 29, make certain saw blade (B) Fig. 28, and splitter (P) Fig. 29, are 90 degrees to the table surface. Once you are certain the splitter is aligned to the saw blade and table, tighten all splitter mounting hardware (D) Fig. 29 and recheck alignment.
13.Holding the clear blade guard, lower the saw blade and assemble the table insert (E) Fig. 30, into the opening on the saw table.
ATTACHING MOTOR COVER
NOTE: IF YOU HAVE AN “LVC” (STARTER BOX) VERSION UNISAW, YOU WILL HAVE TO ATTACH TWO BOTTOM SPRING CLIPS TO THE MOTOR COVER. IF YOU HAVE AN “GPE” (STARTER BOX) VERSION UNISAW THE SPRING CLIPS ARE ALREADY ATTACHED TO THE MOTOR COVER.
1.Attach the two motor cover clips to the motor cover. Align the hole in the motor cover clip with the hole in the motor cover. Place a 13/64 flat washer onto a
2.Place the motor cover (A) in the opening of the Unisaw as shown in Fig. 33. Place the rear motor cover clips inside the motor opening and push the front of the motor cover until all 4 motor cover clips are engaged with the motor cover opening in the Unisaw.
3.Fig. 36 shows the motor cover attached to the Unisaw.
NOTE: TO REMOVE THE MOTOR COVER, PUSH MOTOR COVER TO ONE SIDE TO DEPRESS CLIPS, AND PULL MOTOR COVER OFF.
P
C
D
Fig. 29
E
Fig. 30
A
Fig. 32
A
Fig. 33
15