Hitachi 232133 manual Pressure Transducer Seal, Removal, Installation

Page 28

Pressure Transducer

NOTE: See Fig. 23 and 24 for this procedure.

NOTE: The pressure transducer (67) cannot be re- paired or adjusted. If it malfunctions, replace it.

Removal

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, when instructed to relieve pressure, follow the Pressure Relief Procedure on page 8.

1.Relieve pressure.

2.Remove displacement pump (18). See page 22.

3.Remove front cover (11). Remove screws (25, 26). Lower motor control card.

4.Disconnect harness connector from motor control board (22a). Remove grommet (65).

5.Remove retaining ring (66). Pull pressure trans- ducer down and out past drive housing (2).

6.Guide harness (A) through motor and drive hous- ing and remove pressure transducer.

7.Inspect spacer (68) and seal (69) for damage. Replace seal (69) only if it is cut, nicked, or if leakage occurred. See page 28.

Installation

2.Pass a spacer (68) over harness connector (A) and down into position at bottom of transducer (67).

3.Guide harness up through leg and notch of drive housing (2). Secure guide wire over connector.

4.While pulling guide wire out through bottom of motor, guide harness through drive housing and motor castings.

5.Place grommet (65) over harness and push into position in drive housing hole.

6.Feed excess harness cable through grommet and fully seat transducer body into hole in drive housing leg. Secure it with retaining ring (66).

7.Attach connector to motor control board (22a). Replace cover (11) and heat sink (22). Ensure no wires are pinched between components.

65

A

66

67

68

69

1.Using a small piece of solid copper or mild steel wire (approximately 12 in.), form a small hook and place it in the passage of bottom of the motor. Guide it up and out the hole in the drive housing.

Fig. 24

02996A

Pressure Transducer Seal

NOTE: PTFE seal is unaffected by most solvents and materials. Replace seal only when leakage occurs.

Removal

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, when instructed to relieve pressure, follow the Pressure Relief Procedure on page 8.

28 308801

1.Relieve pressure.

2.Remove displacement pump (18). See page 22.

3.Remove seal (69) from recess in manifold (229).

4.Clean manifold recess with solvent and cloth or cotton swabs. Inspect for nicks or scratches.

Image 28
Contents 308801 Models 232133 and 232131, Series aModel 232132 and 232130, Series a Read and Keep for ReferenceTable of Contents SymbolsInjection Hazard Fire and Explosion Hazard Fire Skin Injection Explosion HazardComponent Function and Identification DC aSetup Model 232133 ShownHow to use the gun safety latch How to use the pressure controlHow to use the pressure drain valve GroundingPressure Relief Procedure How to use the RAC IV tip guardHow to remove a tip clog Injection HazardStartup Adjust spray pattern Fire and Explosion HazardShutdown and Care When to flush How to flushFlushing Relieve pressureOpen or drain position Troubleshooting Basic Problem SolvingElectrical Intermediate Problem Solving Replace pin if missing. Be sure retainer Unit will not run on generator but does run on AC power General Repair Information Tool ListMoving Parts Hazard Fire HazardMotor Test SetupArmature Short Circuit Test Test brushes Motor BrushesElectric Shock Hazard Repairing pump Displacement PumpRemoving pump See Remove three drive housing screws MotorMotor control board diagnostics Motor Control BoardMotor control board removal LED Sprayer Operation Indicates What to do BlinksPower Supply Cord On/Off SwitchDrive Housing, Connecting Rod, Crankshaft Not shown Installation Pressure TransducerPressure Transducer Seal RemovalSuction Hose Models 232132 Drain Valve ReplacementRepair Dimensions Technical DataAccessories Complete Sprayer Parts Model 232132 and 232133, Series a51H 235014 ASSEMBLY, drain valve 240519 CONNECTING, rod assy239769 KIT, pump, displacement See manualModel 232130 and 232131, Series a 239979 CRANKSHAFT, U-695Manual 236352 POTENTIOMETER, pressure adjGraco Standard Warranty Additional Warranty CoveragePhone Number Toll Free