Hitachi 232133 manual Unit will not run on generator but does run on AC power

Page 18

Intermediate Problem Solving

TYPE OF

WHAT TO CHECK

WHAT TO DO

PROBLEM

If check is OK, go to next check

When check is not OK, refer to this column

 

 

 

 

 

Spray Pattern

3.

Check pressure adjustment potentiometer (77) by

 

 

Variations

 

replacing it with a new one.

 

 

(continued)

 

 

 

 

4.

Check Low Output section, page 16.

 

 

 

 

 

 

 

 

 

 

Motor Is Hot and

1.

Determine if sprayer was operated at high pressure

1.

Decrease pressure setting or increase tip

Runs Intermittently

 

with small tips, which causes excessive heat build

 

size.

 

 

up.

 

 

 

 

 

 

 

 

2.

Be sure ambient temperature where sprayer is lo-

2.

Move sprayer to shaded, cooler area if

 

 

cated is no more than 90_F (32_C) and sprayer is

 

possible.

 

 

not located in direct sun.

 

 

 

 

 

 

 

 

3.

Check motor.

3.

Replace motor. See page 23.

 

 

 

 

 

Building Circuit

1.

Check all electrical wiring for damaged insulation,

1.

Repair or replace any damaged wiring or

Breaker Opens As

 

and all terminals for loose fit or damage.

 

terminals. Securely reconnect all wires.

Soon As Sprayer

 

Also check wires between pressure transducer

 

 

Switch Is Turned

 

and motor. See page 23.

 

 

 

 

 

 

On.

 

 

 

 

2.

Check for missing motor brush inspection plate

2.

Correct faulty conditions.

 

 

 

gasket (see page 21), bent terminal forks or other

 

 

 

 

metal to metal contact points which could cause a

 

 

 

 

short.

 

 

 

 

 

 

 

3.Check motor armature for shorts. Use an armature tester (growler) or perform motor test. See page 18. Inspect windings for burns.

3. Replace motor. See page 23.

 

4.

Check motor control board (22a) by performing

4. Replace board. See page 24.

 

 

motor control board diagnostics on page 24. If

 

 

 

diagnostics indicate, substitute with a good board.

 

 

 

CAUTION: Do not perform this check until motor

 

 

 

armature is determined to be good. A bad motor

 

 

 

armature can burn out a good board

 

 

 

 

 

Circuit breaker

1.

Check ‘Basic Problems – Electrical’ on page 14.

 

opens after sprayer

 

 

 

operates for 5 to 10

 

 

 

minutes.

 

 

 

 

 

 

 

Building circuit breaker opens as soon as sprayer is plugged into outlet and sprayer is NOT turned on.

1.Check ON/OFF switch (80). Be sure sprayer is unplugged! Disconnect wires from switch. Check switch with ohmmeter. The reading should be infinity with ON/OFF switch OFF, and zero with switch ON.

CAUTION: A short in motor circuit can damage switch and or motor control board (22a).

1. Replace ON/OFF switch. See page 25.

2.Check for damaged or pinched wires in junction box (20).

2. Replace damaged parts.

Unit will not run on generator but does run on AC power

1.Check the generator’s “peak” voltage. This sprayer will not run if the peak voltage is above 190V or below 100V.

1. Use AC power or a different generator.

18 308801

Image 18
Contents Model 232132 and 232130, Series a 308801Models 232133 and 232131, Series a Read and Keep for ReferenceTable of Contents SymbolsInjection Hazard Fire and Explosion Hazard Fire Skin Injection Explosion HazardComponent Function and Identification DC aSetup Model 232133 ShownHow to use the pressure drain valve How to use the gun safety latchHow to use the pressure control GroundingHow to remove a tip clog Pressure Relief ProcedureHow to use the RAC IV tip guard Injection HazardStartup Adjust spray pattern Fire and Explosion HazardShutdown and Care Flushing When to flushHow to flush Relieve pressureOpen or drain position Troubleshooting Basic Problem SolvingElectrical Intermediate Problem Solving Replace pin if missing. Be sure retainer Unit will not run on generator but does run on AC power Moving Parts Hazard General Repair InformationTool List Fire HazardSetup Motor TestArmature Short Circuit Test Motor Brushes Test brushesElectric Shock Hazard Displacement Pump Repairing pumpRemoving pump See Remove three drive housing screws MotorMotor control board removal Motor control board diagnosticsMotor Control Board LED Sprayer Operation Indicates What to do BlinksPower Supply Cord On/Off SwitchDrive Housing, Connecting Rod, Crankshaft Not shown Pressure Transducer Seal InstallationPressure Transducer RemovalSuction Hose Models 232132 Replacement Drain ValveRepair Technical Data DimensionsAccessories Complete Sprayer Parts Model 232132 and 232133, Series a239769 KIT, pump, displacement 51H 235014 ASSEMBLY, drain valve240519 CONNECTING, rod assy See manualModel 232130 and 232131, Series a Manual 239979CRANKSHAFT, U-695 236352 POTENTIOMETER, pressure adjPhone Number Graco Standard WarrantyAdditional Warranty Coverage Toll Free