Pressure Transducer Seal

Installation

1.Lightly coat cleaned packing recess in manifold with a light grease or oil.

2.Heat seal (69) in hot water for several minutes.

CAUTION

Excess pressure from the probes or fingernails will damage the packing and cause subsequent leakage.

3.Use a blunt wooden or plastic probe and install seal (69) into recess in manifold (229). Be careful not to cause kinks or bends in packing during installation.

4.Lightly grease or oil transducer (67) and install pump (18). See page 22.

69

229

Fig. 25

7743A

 

Suction Hose (Models 232132 and 232133)

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, when instructed to relieve pressure, follow the Pressure Relief Procedure on page 8.

1.Relieve pressure.

2.Remove drain hose (50) from clip.

3.Pull upward on suction hose (47) while unscrewing it from inlet tube (43). The hose coupling (A) threads will engage and the hose will separate from the tube.

4.Replace o-ring (45) if it is worn or damaged.

5.Lubricate o-ring (45) and inlet tube (43) threads with light grease.

6.Align suction hose coupling (A) with threads of inlet tube (43). Tighten hose onto tube at least 4 turns to ensure that threads have disengaged and can function as a swivel joint.

CAUTION

Misalignment or cross-threading will damage the parts and/or create shavings which can cause the o-ring (45) to leak.

 

50

 

 

47

 

1

45

Lubricate with

1

1

A

light grease.

 

Fig. 26

43

7744A

 

 

308801 29

Image 29
Contents Models 232133 and 232131, Series a 308801Model 232132 and 232130, Series a Read and Keep for ReferenceSymbols Table of ContentsInjection Hazard Fire Skin Injection Explosion Hazard Fire and Explosion HazardDC a Component Function and IdentificationModel 232133 Shown SetupHow to use the pressure control How to use the gun safety latchHow to use the pressure drain valve GroundingHow to use the RAC IV tip guard Pressure Relief ProcedureHow to remove a tip clog Injection HazardStartup Fire and Explosion Hazard Adjust spray patternShutdown and Care How to flush When to flushFlushing Relieve pressureOpen or drain position Basic Problem Solving TroubleshootingElectrical Intermediate Problem Solving Replace pin if missing. Be sure retainer Unit will not run on generator but does run on AC power Tool List General Repair InformationMoving Parts Hazard Fire HazardArmature Short Circuit Test SetupMotor Test Electric Shock Hazard Motor BrushesTest brushes Removing pump See Displacement PumpRepairing pump Motor Remove three drive housing screwsMotor Control Board Motor control board diagnosticsMotor control board removal LED Sprayer Operation Indicates What to do BlinksOn/Off Switch Power Supply CordDrive Housing, Connecting Rod, Crankshaft Not shown Pressure Transducer InstallationPressure Transducer Seal RemovalSuction Hose Models 232132 Repair ReplacementDrain Valve Accessories Technical DataDimensions Model 232132 and 232133, Series a Complete Sprayer Parts240519 CONNECTING, rod assy 51H 235014 ASSEMBLY, drain valve239769 KIT, pump, displacement See manualModel 232130 and 232131, Series a CRANKSHAFT, U-695 239979Manual 236352 POTENTIOMETER, pressure adjAdditional Warranty Coverage Graco Standard WarrantyPhone Number Toll Free