Pressure Transducer Seal
Installation
1.Lightly coat cleaned packing recess in manifold with a light grease or oil.
2.Heat seal (69) in hot water for several minutes.
CAUTION
Excess pressure from the probes or fingernails will damage the packing and cause subsequent leakage.
3.Use a blunt wooden or plastic probe and install seal (69) into recess in manifold (229). Be careful not to cause kinks or bends in packing during installation.
4.Lightly grease or oil transducer (67) and install pump (18). See page 22.
69
229
Fig. 25 | 7743A |
|
Suction Hose (Models 232132 and 232133)
WARNING
INJECTION HAZARD
To reduce the risk of serious injury, when instructed to relieve pressure, follow the Pressure Relief Procedure on page 8.
1.Relieve pressure.
2.Remove drain hose (50) from clip.
3.Pull upward on suction hose (47) while unscrewing it from inlet tube (43). The hose coupling (A) threads will engage and the hose will separate from the tube.
4.Replace
5.Lubricate
6.Align suction hose coupling (A) with threads of inlet tube (43). Tighten hose onto tube at least 4 turns to ensure that threads have disengaged and can function as a swivel joint.
CAUTION
Misalignment or
| 50 |
| |
| 47 |
| |
1 | 45 | Lubricate with | |
1 | 1 | ||
A | light grease. | ||
| |||
Fig. 26 | 43 | 7744A | |
|
|
308801 29