Haier 232738 specifications General Problem Circuit Breaker is Tripping, Thermal Overload

Page 13

 

 

Advanced Troubleshooting

 

 

 

 

Specific Problem

Cause

Solution

 

 

 

 

 

 

 

 

Sprayer Wiring Problems

Motor thermal overload cutoff

1. Unplug sprayer electrical cord.

(cont.)

switch damaged.

2. Remove motor harness from control card

 

Thermal Overload, page 7.

3. Check for continuity between yellow leads

 

 

or motor harness.

 

 

4. If thermal relief switch is open (no continu-

 

 

ity) allow motor to cool.

 

 

5. If switch remains open after motor cools,

 

 

replace motor using Motor Kit, page 18.

 

 

6. If thermal relief switch closes after motor

 

 

cools, find correct cause of overheating.

 

 

 

 

 

Terminals are damaged or

Replace any damaged terminals. Make sure all

 

loose

terminal connections are tight.

 

 

 

 

 

General Problem: Circuit Breaker is Tripping

 

 

 

 

 

 

 

 

Specific Problem

Cause

Solution

 

 

 

 

 

 

Building circuit breaker opens

Sprayer electrical wiring is

Repair or replace any damaged wiring or

as soon as sprayer is turned on

pinched or insulation is

terminals. Securely reconnect wires.

 

damaged.

 

 

 

 

 

 

 

Wires between pressure

 

 

 

control switch and control

 

 

 

board are pinched

 

 

 

 

 

 

Motor armature is shorting

Check for shorts using armature tester (growler)

 

 

or perform spin test, Motor Diagnostics, page

 

 

19. If shorts are evident, replace motor using

 

 

Motor Kit, page 18.

 

 

 

 

Control board is damaged.

See Control Board Diagnostics, page 19.

 

CAUTION: Do not perform

Replace control board if damaged using Control

 

control board diagnostics until

Board Kit, page 18.

 

you have determined the

 

 

 

armature is good. A bad motor

 

 

 

armature can burn out a good

 

 

 

motor control board.

 

 

 

 

 

 

309477F

13

Image 13
Contents US Patent 6,752,067 Europe Patent 1 208 Airless SprayerContents Manual Conventions SpecificationsFire and Explosion Hazard Equipment Misuse Hazard Pressure Relief Procedure Thermal Overload Grounding and Electrical RequirementsGeneral Repair Information Problem Cause Solution Basic TroubleshootingService, page 20. Do not store in water See Motor Does Not Operate,Switch Kit, Control Switch Kit,See Low or Fluctuating Output, Thermal Overload,General Problem Motor Does Not Operate Advanced TroubleshootingSee Control Board Diagnostics, General Problem Circuit Breaker is Tripping OFF General Problem Erratic Motor OperationPrime/Spray Drain Valve Kit, General Problem Low or Fluctuating OutputGrounding and Electrical Requirements, See Control Board Diagnostics, page 19. If General Problem Excessive Pressure Build Up General Problem No OutputNecessary using Pressure Control Switch Kit Kit Number Models/Series Kit Description List of KitsSetup XR9 model only Motor DiagnosticsBoth Models Armature Short Circuit Spin Test XR9 model onlyPump Diagnostics Control Board DiagnosticsPump Service Dx Pressure Roller/Spray System PartsDescription Description QtyDx Pressure Roller/Spray System Model Pressure Roller AssemblyModel 232751, 232752 XR9 Spray SystemXR9 Spray System XR9 Spray System Model 232751, 232752, 232753 Series C XR9 Spray System Labels Dx Roller/Spray System XR9 Sprayer Technical DataFor Graco Canada Customers Graco WarrantyGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN