Haier 232738 specifications See Control Board Diagnostics, page 19. If

Page 16

 

 

Advanced Troubleshooting

 

 

 

Specific Problem

Cause

Solution

 

 

 

 

 

 

 

Control board is damaged.

See Control Board Diagnostics, page 19. If

 

CAUTION: Do not perform

damaged replace control board using Control

 

control board diagnostics until

Board Kit, page 18.

 

you have determined the

 

 

armature is good. A bad motor

 

 

can burn out a good control

 

 

board.

 

 

 

 

Motor runs and pump cycles,

Intake valve ball or outlet valve

Remove and clean valves and check balls and

but pressure does not build up

ball is not seating properly

seats for nicks; replace if necessary. Strain paint

 

 

before spraying to remove particles that could clog

 

 

pump. Pump Service, page 20.

 

 

 

 

Pump packings are worn or

Check for leaking around throat packing nut.

 

damaged

Replace pump packings if there are leaks. Pump

 

 

Service, page 20.

 

 

 

 

Prime/Spray Valve leaking

Check Prime/Spray Valve for debris trapped on

 

 

seat and for worn parts. Torque to 21 N•m (185

 

 

in-lb). If parts are worn, replace valve using

 

 

Prime/Spray Drain Valve Kit, page 18.

 

 

 

Spray pattern has variations,

Leads from motor or pressure

Be sure terminals are centered and firmly

pressure fluctuates

switch to control board are

connected. Inspect wiring insulation and terminals

excessively, or motor runs very

damaged, loose or overheated

for signs of overheating. Replace any loose

slowly

 

terminals or damaged wiring. Securely reconnect

 

 

terminals.

 

 

 

 

Pressure control switch leads

Make sure pressure control harness is routed

 

are pinched between pump

behind pump, through retention clip and

 

and drive housing or between

connected to control board connector on control

 

front cover and drive housing

board (connect with tab to right).

 

(XR9 only)

 

 

 

 

 

Control board is damaged.

See Control Board Diagnostics, page 19. If

 

CAUTION: Do not perform

damaged, replace control board using Control

 

control board diagnostics until

Board Kit, page 18.

 

you have determined the

 

 

armature is good. A bad

 

 

armature can burn out a good

 

 

control board.

 

 

 

 

 

Pressure control switch is

Replace pressure control switch using Pressure

 

damaged or worn out

Control Switch Kit, page 18.

 

 

 

16

309477F

Image 16
Contents Airless Sprayer US Patent 6,752,067 Europe Patent 1 208Contents Specifications Manual ConventionsFire and Explosion Hazard Equipment Misuse Hazard Pressure Relief Procedure Grounding and Electrical Requirements Thermal OverloadGeneral Repair Information Basic Troubleshooting Problem Cause SolutionService, page 20. Do not store in water See Motor Does Not Operate,Control Switch Kit, Switch Kit,See Low or Fluctuating Output, Thermal Overload,Advanced Troubleshooting General Problem Motor Does Not OperateSee Control Board Diagnostics, General Problem Circuit Breaker is Tripping General Problem Erratic Motor Operation OFFPrime/Spray Drain Valve Kit, General Problem Low or Fluctuating OutputGrounding and Electrical Requirements, See Control Board Diagnostics, page 19. If General Problem Excessive Pressure Build Up General Problem No OutputNecessary using Pressure Control Switch Kit List of Kits Kit Number Models/Series Kit DescriptionMotor Diagnostics Setup XR9 model onlyBoth Models Armature Short Circuit Spin Test XR9 model onlyPump Diagnostics Control Board DiagnosticsPump Service Parts Dx Pressure Roller/Spray SystemDescription Description QtyDx Pressure Roller/Spray System Pressure Roller Assembly ModelXR9 Spray System Model 232751, 232752XR9 Spray System XR9 Spray System Model 232751, 232752, 232753 Series C XR9 Spray System Labels Technical Data Dx Roller/Spray System XR9 SprayerGraco Warranty For Graco Canada CustomersGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN