42VMC
Electrical connections
Heat pump
E N G L I S H
Unit | 42VMC 009, 012, 014 |
System |
L N NY O W2
L N N Y O W2
50Hz~ 230V
N Y O W2
Unit
42VMC 018, 024
System
R C YO W2 S
50Hz~
230V
R C Y O W2 S
L N R C Y O W2 S
|
|
|
| Minimum connection wire size between |
|
| ||||
|
|
|
|
| indoor and outdoor units (mm2) |
|
| |||
Model | L | N | N | R | C | Y | O |
| W2 | S |
|
|
|
|
|
|
|
|
|
|
|
42VMC 009 | 2.5 | 2.5 | 1.5 | – | – | 1.5 | 1.5 |
| 1.5 | – |
|
|
|
|
|
|
|
|
|
|
|
42VMC 012, 014 | 2.5 | 2.5 | 2.5 | – | – | 2.5 | 2.5 |
| 2.5 | – |
|
|
|
|
|
|
|
|
|
|
|
42VMC 018, 024 | – | – | – | 1.5 | 1.5 | 1.5 | 1.5 |
| 1.5 | 1.5 |
|
|
|
|
|
|
|
|
|
|
|
Terminal box legend
Earth.
LLive power supply.
N Neutral power supply.
N Neutral connection indoor/outdoor unit. R Live connection indoor/outdoor unit.
C Neutral connection indoor/outdoor unit. Y Compressor interlocking contact.
O Reversing valve control.
W2 Outdoor fan signal.
SDefrost end signal.
10120
10 100
Mains supply connecting cable
(field wiring).
Connecting cable,
Indoor unit
Outdoor unit
Main switch
GB - 11