Graco 311320H important safety instructions Initial Set Up, Valving Rod Closed Position

Page 11

Initial Set Up

1.Remove coupling block from gun.

2.Check valving rod clearance in closed posi- tion. Rod should extend approximately 1/32 in. (1 mm) beyond tip of mixing chamber. If it does not, see Valving Rod Adjustment procedure, page 21.

1/32 in.

FIG. 9: Valving Rod (Closed Position)

3.Adjust valving rod travel to initial setting.

a.Loosen friction lock. Turn valving rod adjustment screw clockwise until it stops.

b.Turn valving rod adjustment screw 11 turns counterclockwise.

4.Connect air supply hose to gun.

5.Connect A-isocyanate hose (red-taped) to notched fitting on coupling block. Then con- nect R-resin hose (blue-taped) to fitting without notches on coupling block.

6.Close both manual valves.

7.Pressurize the A and R chemical hoses and check for leaks. (See Proportioning Unit manual.)

8.Bleed air from chemical hoses:

a.Hold coupling block with exit ports pointed into disposable container.

Initial Set Up

b.Open each manual valve to allow trapped air to escape. Bleed each side until chemical is free of air.

c.Close both manual valves.

9.Use clean cloth soaked in gun cleaner to wipe clean coupling block and its mating surfaces.

CAUTION

To avoid accumulation of dirt and other con- taminants, do not apply grease to mating surfaces of coupling block.

10.Install coupling block to gun block.

11.Proceed with Daily Start-up procedure or Shutdown procedure as required.

311320H

11

Image 11
Contents Model D Spray Gun Important Safety InstructionsModels ContentsPersonal Protective Equipment Fire and Explosion Hazard Major Components Overall ViewCenterline Components Centerline ComponentsKeep a and B Components Separate Operation BasicsGrounding Isocyanate HazardRemove Coupling Block Manual ValvesAir Hose Connection Valving Rod Adjustment ScrewFelt Wiper Air Cap Adjustment ValveAdjust Felt Wiper Clean Felt WiperValving Rod Closed Position Initial Set UpDaily Shutdown Daily Start-UpPressure Relief Procedure Point of Valving Spray Pattern AdjustmentTern opens as adjustment is made FIG Distance of Gun Chamber Minimum Maximum From Surface Valving Rod Adjustment for Standard Mixing ChambersTurns Out From Point Recommended Gun Service Kits MaintenanceClean Spray Gun Procedure Repair Filter Screen Removal and ServiceCheck Valves Clean Injection SlotsNot Remove Valving Rod AdjustmentMixing Chamber Removal Centerline Component RemovalSleeve Removal Block Chamber Seating Centerline Component InstallationRepair Parts Model D Spray Gun AssemblyNo. Part No. Description Model D Spray Gun AssemblyAC chamber Standard Mixing Chambers Part Number Air Cylinder AssemblyModel Coupling Block Assembly311320H Category Data Technical DataGraco Information Graco Standard Warranty