Spray Pattern Adjustment
e.If buildup recurs shortly after cleaning tip, remove air cap and ensure inside is clean.
Reinstall air cap and ensure airflow is properly set.
If no buildup occurred on air cap, check the fol- lowing items in this order and readjust if neces- sary:
•Check Valving Rod Adjustment Screw/Sleeve setting.
•Check hose temperature setting.
•Check primary heater temperature setting.
•Ensure spray pressures between chemi- cals are balanced. If they are not, refer to Troubleshooting section of Proportioning Unit Operation Manual for the proportioner in use.
•Ensure flow of air to air cap is adequate but not excessive.
| Turns Out From Point of | Recommended |
|
| |
| Valving |
|
| ||
| Distance of Gun |
|
| ||
|
|
|
|
| |
Chamber | Minimum | Maximum | from Surface | Pattern Size | |
|
|
|
|
| |
|
|
|
|
|
|
1/2 turn | 2 turns | 12 in. | 6 in. (152.4 mm) | ||
|
|
|
|
| |
1/2 turn | 2 turns | 12 in. | 6 in. (152.4 mm) | ||
|
|
|
|
| |
1 3/4 turns | 2 5/8 turns | 18 to 20 in. (457.2 | 8 in. (203.2 to | ||
|
|
| to 508 mm) | 228.6 mm) | |
|
|
|
|
| |
62 | 2 turns | 3 turns | 18 to 20 in. (457.2 | 8 to 9 in. (203.2 | |
|
|
| to 508 mm) | to 228.6 mm) | |
|
|
|
|
| |
70 | 2 turns | 3 turns | 18 to 20 in. (457.2 | 10 to 12 in. (254 | |
|
|
| to 508 mm) | to 304.8 mm) | |
|
|
|
|
| |
2 turns | 3 turns | 24 in. (609.6 mm) | 14 in. (355.6 mm) | ||
|
|
|
|
|
|
Table 1: Valving Rod Adjustment for Standard Mixing Chambers
16 | 311320H |