Graco 311320H important safety instructions Valving Rod Adjustment, Not Remove

Page 21

Valving Rod Adjustment

In closed position, valving rod should extend approximately 1/32 in. (1 mm) beyond tip of mixing chamber. If it does not, follow this pro- cedure:

1/32 in.

FIG. 19: Valving Rod (Closed Position)

1.Perform Pressure Relief Procedure (page 13) and Clean Spray Gun Procedure, page 18.

2.Disconnect air supply from gun.

3.Remove spring retainer case. Firmly grasp spring retainer case, push in and rotate counterclockwise. Pull spring out of air cyl- inder.

Spring Retainer Case

Spring

FIG. 20: Retainer Case Removal

4.Loosen felt wiper retainer 2-3 turns (DO

NOT REMOVE).

Repair

5.Remove valving rod. Push back firmly on piston rod until end of Stop Bar emerges from cylinder.

Positioner

Stop Bar

FIG. 21: Valving Rod Removal

6.Loosen stop bar from positioner. Turn posi- tioner to adjust length of valving rod as required. Retighten stop bar against posi- tioner.

7.Replace valving rod, spring, and spring retainer case. Grasp firmly, push in, and turn clockwise to lock in place.

8.Adjust felt wiper and soak with gun cleaner.

9.Connect air supply to gun.

10.Check action of valving rod. With manual valves closed, press trigger several times and ensure valving rod moves freely.

If you have encountered no problems, spray gun is ready for test spray. Follow Daily Start-up procedure (page 12) and Spray Pat- tern Adjustment procedure (page 14).

311320H

21

Image 21
Contents Model D Spray Gun Important Safety InstructionsModels ContentsPersonal Protective Equipment Fire and Explosion Hazard Major Components Overall ViewCenterline Components Centerline ComponentsGrounding Operation BasicsIsocyanate Hazard Keep a and B Components SeparateRemove Coupling Block Manual ValvesAir Hose Connection Valving Rod Adjustment ScrewAdjust Felt Wiper Air Cap Adjustment ValveClean Felt Wiper Felt WiperValving Rod Closed Position Initial Set UpDaily Shutdown Daily Start-UpPressure Relief Procedure Point of Valving Spray Pattern AdjustmentTern opens as adjustment is made FIG Valving Rod Adjustment for Standard Mixing Chambers Turns Out From Point RecommendedDistance of Gun Chamber Minimum Maximum From Surface Gun Service Kits MaintenanceClean Spray Gun Procedure Repair Filter Screen Removal and ServiceCheck Valves Clean Injection SlotsNot Remove Valving Rod AdjustmentMixing Chamber Removal Centerline Component RemovalSleeve Removal Block Chamber Seating Centerline Component InstallationRepair Parts Model D Spray Gun AssemblyNo. Part No. Description Model D Spray Gun AssemblyAC chamber Standard Mixing Chambers Part Number Air Cylinder AssemblyModel Coupling Block Assembly311320H Category Data Technical DataGraco Information Graco Standard Warranty