Repair

Clean Injection Slots

1.Perform Pressure Relief Procedure (page 13) and Clean Spray Gun Procedure, page 18.

2.Remove check valves.

A-Iso Check Valve (tall hexhead)

Clean-out Port (both sides)

R-Resin Check Valve (short hexhead)

FIG. 18: Check Valves

3.Inspect check valves to ensure sleeve is secured, and place check valves in sepa- rate containers of gun cleaner.

4.Flush cleanout ports with gun cleaner.

5.Turn valving rod adjustment screw one full turn counterclockwise to ensure valving rod will be withdrawn completely past injection slot.

6.Clean mixing chamber injection slots. With air supply connected to gun, depress and hold trigger to keep valving rod in open position. Insert appropriate cleanout spade into cleanout hole and mixing chamber.

CAUTION

To prevent damage to chamber, do not release trigger while cleanout spade is in chamber slot.

7.Flush injection slots. With valving rod in open position, flush each injection slot with gun cleaner. Press flush can needle firmly into cleanout hole to create seal. Continue until gun cleaner sprays out chamber tip.

8.Inspect and clean check valves, page 22.

9.Install tall hexhead check valve on Isocya- nate side, and short hexhead on Resin side.

10.Adjust valving rod adjustment screw one turn clockwise.

20

311320H

Image 20
Contents Important Safety Instructions Model D Spray GunContents ModelsPersonal Protective Equipment Fire and Explosion Hazard Overall View Major ComponentsCenterline Components Centerline ComponentsOperation Basics GroundingIsocyanate Hazard Keep a and B Components SeparateManual Valves Remove Coupling BlockValving Rod Adjustment Screw Air Hose ConnectionAir Cap Adjustment Valve Adjust Felt WiperClean Felt Wiper Felt WiperInitial Set Up Valving Rod Closed PositionDaily Start-Up Daily ShutdownPressure Relief Procedure Spray Pattern Adjustment Point of ValvingTern opens as adjustment is made FIG Distance of Gun Chamber Minimum Maximum From Surface Valving Rod Adjustment for Standard Mixing ChambersTurns Out From Point Recommended Maintenance Gun Service KitsClean Spray Gun Procedure Filter Screen Removal and Service RepairClean Injection Slots Check ValvesValving Rod Adjustment Not RemoveCenterline Component Removal Mixing Chamber RemovalSleeve Removal Block Centerline Component Installation Chamber SeatingRepair Model D Spray Gun Assembly PartsModel D Spray Gun Assembly No. Part No. DescriptionAC chamber Standard Mixing Chambers Air Cylinder Assembly Part NumberCoupling Block Assembly Model311320H Technical Data Category DataGraco Standard Warranty Graco Information