Graco 311320H important safety instructions Centerline Component Installation, Chamber Seating

Page 24

Repair

Centerline Component Installation

All gun block parts must be clean and free of damage before installation.

1.Remove felt wiper assembly from rear of mixing chamber.

2.Ensure internal mixing chamber parts are in place.

3.Insert chamber into gun block. Align key- way in chamber with pin protruding from top of hole in block.

5.Thread felt wiper assembly into back of mixing chamber. Do not tighten.

CAUTION

Failure to install felt wiper in rear of chamber allows internal chamber parts to fall out when chamber is tapped into place.

6.With rear of gun block facing palm of your hand, place mixing chamber insertion block over nose of chamber so it rests squarely on the chamber flange. Firmly tap insertion block with hammer until flange of chamber is flush with face of gun block (FIG. 27).

Chamber Insertion Block

FIG. 27: Chamber Seating

FIG. 25: Mixing Chamber Insertion

4.Press chamber into block so that flange is 1/32 - 1/16 in. above face of gun block.

1/32 in.

1/16 in.

FIG. 26: Chamber Positioning

7.With o-ring in place on underside of gun frame, assemble block to frame.

8.Install valving rod assembly. If using new felt wiper, push valving rod through felt with retainer case off chamber. Remove felt wiper and any felt buildup on tip of rod. Install wiper, hand tighten into rear of chamber in gun block. Then insert valving rod through piston in air cylinder, guiding it through center of felt wiper retainer. Use firm pressure to carefully push valving rod into mixing chamber until piston of air cylin- der bottoms out.

9.Check valving rod clearance. If it does not extend approximately 1/32 in. (1mm) beyond tip of mixing chamber, see Valving Rod Adjustment, page 21.

24

311320H

Image 24
Contents Important Safety Instructions Model D Spray GunContents ModelsPersonal Protective Equipment Fire and Explosion Hazard Overall View Major ComponentsCenterline Components Centerline ComponentsOperation Basics GroundingIsocyanate Hazard Keep a and B Components SeparateManual Valves Remove Coupling BlockValving Rod Adjustment Screw Air Hose ConnectionAir Cap Adjustment Valve Adjust Felt WiperClean Felt Wiper Felt WiperInitial Set Up Valving Rod Closed PositionDaily Start-Up Daily ShutdownPressure Relief Procedure Spray Pattern Adjustment Point of ValvingTern opens as adjustment is made FIG Valving Rod Adjustment for Standard Mixing Chambers Turns Out From Point RecommendedDistance of Gun Chamber Minimum Maximum From Surface Maintenance Gun Service KitsClean Spray Gun Procedure Filter Screen Removal and Service RepairClean Injection Slots Check ValvesValving Rod Adjustment Not RemoveCenterline Component Removal Mixing Chamber RemovalSleeve Removal Block Centerline Component Installation Chamber SeatingRepair Model D Spray Gun Assembly PartsModel D Spray Gun Assembly No. Part No. DescriptionAC chamber Standard Mixing Chambers Air Cylinder Assembly Part NumberCoupling Block Assembly Model311320H Technical Data Category DataGraco Standard Warranty Graco Information