Graco 310649C important safety instructions Turn on proportioner

Page 12

Setup

7. Actuate gun to check for full mix chamber travel.

Front of air cap (C) should be approximately flush with front retaining ring (U).

U

C

TI4766a

8. Open cleanoff air valve (K) 1/4-1/2 turn and

actuate air line to check that cleanoff air is flowing. Adjust as desired.

K

11. Open B (RESIN) fluid valve (about three half

turns). Then open A (ISO) fluid valve.

TI4752A

12. Disengage piston safety lock.

TI3849

13. Test spray onto card board. Adjust pressure and

9. Engage piston safety lock.

temperature to get desired results.

TI2409A

10. Turn on proportioner.

TI4763A

14. Apply layer of lubricant over front of gun and

lock ring, or use gun cover to prevent overspray buildup and ease disassembly. See Fusion Gun Manual 309856 or 309550 to order lubricant and gun cover

15. Gun is ready to spray.

CAUTION

Air supply is required for gun actuation. Do not dis- connect gun air supply until fluid pressure is relieved, see page 13.

12

310649C

Image 12
Contents Important Safety Instructions Automatic Plural Component, Impingement Mix Spray GunContents Manual ConventionsAir Purge Guns Round Pattern GunsFlat Pattern Guns Related ManualsMechanical Purge Guns Standard Round Pattern GunsDirect Impingement Round Pattern Guns Direct Impingement Flat Pattern GunsSkin Injection Hazard Isocyanate Hazard Keep a and B Components Separate Burn HazardPiston Safety Lock Follow Pressure Relief Procedure,Grounding Turning Air CapOverall View Mechanical Purge Gun ShownKey Installation Mounting gun to rodMounting gun to stationary support or robot arm Connecting airline and accessories Setup ISOTurn on proportioner Pressure Relief Procedure Shutdown 310649C Parts Air Purge GunPart No. Description Qty ManifoldMechanical Purge Gun DetailAIR CAP Mounting Dimensions Technical Data AccessoriesCategory Data Part No. DescriptionGraco Standard Warranty Graco InformationToll Free