Accessory Fluid Filter Kit

Accessory Fluid Filter Kit

Fluid Filter Kit 240–440

Ref.

Part No.

Description

Qty.

No.

101

114–361

FILTER, fluid

1

102

113–322

CONNECTOR, male

1

103

054–188

TUBE; PTFE;R3/8” O.D.

8 in.

104

113–534 ELBOW, male x female

2

105

111–917

NIPPLE; Nylon

1

The Fluid Filter Kit, listed above, can be installed to filter fluid drawn by the suction tube after it comes out of the pump. Install the Fluid Filter Kit as follows (see Fig. 3):

1.Apply thread sealant (specified in Fig. 3) to all male threads in this kit.

2.Remove the elbow (40) from the pump outlet, and remove the tube (16). See the Parts drawing on page 11.

3.Thread one the elbows (104) into the pump outlet.

4.Assemble the nipple (105) and the other elbow (104)

5.Thread the nipple (105), with the elbow (104) attached to it, into the elbow (104) that you threaded into the pump outlet.

6.Thread the fluid filter (101) onto the male threads of the elbow (104).

7.Thread the male connector (102) into the fluid filter (101).

8.Turn the fluid filter/male connector assembly towards the elbow (39). This makes connecting the tube (103) in step 9 easier.

9.Cut the PTFERtube (103) to the proper length, and install it to run from the male connector (102) to the elbow (39).

{To avoid sharp bends in the tube, you may have to cut it to a shorter length.

}Apply Graco Thread Sealer, or LoctiteR 567, or equiv- alent to male threads.

YFor initial installation, make sure the dome is firmly hand tightened onto the filter body. Do not use a tool. During subsequent service, hand tighten more firmly to prevent drips.

39

103{

103}

102}

Fluid Filter Kit 240–440 101Y 104}

105}

104}

Fig. 3

8157A

 

 

14 308-845

Image 16
Contents INSTRUCTIONS-PARTS LIST Metal fluid fittings and hose couplings are stainless steel100 psi 0.7 MPa, 7 bar Maximum Fluid Working Pressure 100 psi 0.7 MPa, 7 bar Maximum Air Inlet PressureImprove pressure control instructions Graco Ref Instruction Manual - Parts List Changes308845 1A 308845 1B Table of Contents SymbolsWarning Symbol Caution SymbolEQUIPMENT MISUSE HAZARD TOXIC FLUID HAZARDSetup General InformationPreparing the Operator Preparing the SiteAssembling the Wall-Mount Unit Hose ConnectionsFlush Pump Before First Use GroundingUsing the Gun Pressure Relief ProcedureAdjusting Pump and Gun Air Regulators OperationDelta Spray Priming the System See Figregulated Air Spray package or regulated HVLP package shown When to Shut Down the System Flushing the System1. Relieve the pressure 12. Relieve the pressureMaintenance Front Shield AssemblyFront Shield Assembly Orderable Parts Back ShieldParts List Wall-Mount Packages with Fluid Pressure RegulatorsParts Drawing Grounding DetailWall-Mount Packages with Surge Tanks 8089A Accessory Fluid Filter Kit Fluid Filter KitTechnical Data DimensionsWall Mounting Hole Layout CategoryGraco Phone Number Graco Standard WarrantyFOR GRACO CANADA CUSTOMERS