Graco Inc 240-363 Assembling the Wall-Mount Unit, Hose Connections, Flush Pump Before First Use

Page 7
Assembling the Wall-Mount Unit

Setup

Assembling the Wall-Mount Unit

See Fig. 1

Install the wall bracket (G) 5 ft (1.5 m) above the floor. For proper hole dimensions, use the Wall Mounting Hole Layout on page 15. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.

Screw the bung plug (R) into the drum bung opening. Adjust the suction tube (L) so the end of the tube is about 1/2 in. (13 mm) off the bottom of the drum, and secure the suction tube using the thumbscrew on the bung plug.

Hose Connections

This package is shipped with the hoses connected. Before you disconnect any hoses, make a note of the proper connections.

Flush Pump Before First Use

The pump was tested in water. If the test solution could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing the System on page 8.

Grounding

WARNING

To reduce the risk of static sparking, the entire system must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Ground all of this equipment. Also read FIRE AND EXPLOSION HAZARD on page 2.

DPump: One end of the ground wire is already connected to the pump grounding strip. Connect the clamp end of the ground wire to a true earth ground.

DAir compressor: Follow the manufacturer’s recommendations.

DObject being sprayed: Follow the local code.

DFluid supply container: Follow the local code.

DAll solvent pails used when flushing: Follow the local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

DSystems with PRO 3500sc and PRO 4500sc electrostatic gun: Make sure you read all of the grounding instructions and warnings in your gun instruction manual.

308-845 5

Image 7
Contents 100 psi 0.7 MPa, 7 bar Maximum Air Inlet Pressure INSTRUCTIONS-PARTS LISTMetal fluid fittings and hose couplings are stainless steel 100 psi 0.7 MPa, 7 bar Maximum Fluid Working PressureImprove pressure control instructions Graco Ref Instruction Manual - Parts List Changes308845 1A 308845 1B Caution Symbol Table of ContentsSymbols Warning SymbolTOXIC FLUID HAZARD EQUIPMENT MISUSE HAZARDPreparing the Site SetupGeneral Information Preparing the OperatorGrounding Assembling the Wall-Mount UnitHose Connections Flush Pump Before First UseOperation Using the GunPressure Relief Procedure Adjusting Pump and Gun Air RegulatorsDelta Spray Priming the System See Figregulated Air Spray package or regulated HVLP package shown 12. Relieve the pressure When to Shut Down the SystemFlushing the System 1. Relieve the pressureBack Shield MaintenanceFront Shield Assembly Front Shield Assembly Orderable PartsWall-Mount Packages with Fluid Pressure Regulators Parts ListGrounding Detail Parts DrawingWall-Mount Packages with Surge Tanks 8089A Fluid Filter Kit Accessory Fluid Filter KitCategory Technical DataDimensions Wall Mounting Hole LayoutGraco Phone Number Graco Standard WarrantyFOR GRACO CANADA CUSTOMERS