Removal

WARNING

Read Electric Shock Warning, page 3 and Pressure Relief Procedure, page 8.

1.Relieve pressure, page 8. Disconnect power cord from outlet.

2.Remove two screws (30) and shroud (29).

100

30101

29

Fan Replacement

3.Remove spring clip (101) on back of motor.

4.Pull off fan (100).

Installation

1.Slide new fan (100) in place on back of motor. Be sure blades of fan face motor as shown.

2.Install spring clip (101).

3.Replace shroud (29) and two screws (30).

ti5769a

18

310824D

Image 18
Contents Stand Hi-Boy ProStepContents Manual ConventionsGrounding Instructions GroundingFire and Explosion Hazard Equipment Misuse Hazard Component Identification Component IdentificationInstallation Grounding and Electric RequirementsPressure Relief Procedure General Repair Information Troubleshooting Motor Won’t OperatePower Cord Replacement Cord. See page 7, Grounding and Electric 14, Displacement Pump Replacement Displacement Pump Replacement RemovalInstallation Drive Housing Replacement Spin Test Armature Short Circuit TestFan Replacement Motor Brush Replacement Control Board Replacement 120V Fuse Replacement Pressure Control Assembly Replacement Manifold Replacement Drain Line Replacement RemovalPower Cord Replacement Motor Replacement Wiring Diagram 120V ModelTechnical Data Graco Standard Warranty For Graco Canada Customers