Graco Inc ti5638a, 309639, 309250, 310820, 310876, 310824D, 256481 Drain Line Replacement, Removal

Page 25

Drain Line Replacement

Drain Line Replacement

This procedure should be used whenever you replace the manifold and reinstall an existing drain line or install a new drain line using the Drain Line Kit.

Removal

To remove the drain line (40) from the manifold:

1. Cut drain line (40) from barbed fitting (20).

2. Unscrew barbed fitting (20) from manifold.

If you are only replacing the manifold and will be reusing the existing barbed fitting (20) and drain line (40), you will need to use a sharp knife to cut the remaining drain line material off the end of the barbed fitting (20).

Installation

1.Screw barbed fitting (20) into manifold.

2.Push drain line (40) onto barbed fitting (20).

To make the drain line more pliable and easier to install over barbed fitting, heat end of drain line (40) with a hair dryer or by placing end in hot water a few seconds.

310824D

25

Image 25
Contents Hi-Boy ProStep StandManual Conventions ContentsGrounding Grounding InstructionsFire and Explosion Hazard Equipment Misuse Hazard Component Identification Component IdentificationGrounding and Electric Requirements InstallationPressure Relief Procedure General Repair Information Motor Won’t Operate TroubleshootingPower Cord Replacement Cord. See page 7, Grounding and Electric 14, Displacement Pump Replacement Removal Displacement Pump ReplacementInstallation Drive Housing Replacement Armature Short Circuit Test Spin TestFan Replacement Motor Brush Replacement Control Board Replacement 120V Fuse Replacement Pressure Control Assembly Replacement Manifold Replacement Removal Drain Line ReplacementPower Cord Replacement Motor Replacement 120V Model Wiring DiagramTechnical Data For Graco Canada Customers Graco Standard Warranty