Power Cord Replacement
See Wiring Diagram, page 28.
WARNING
Read Electric Shock Warning, page 3 and Pressure Relief Procedure, page 8.
Removal
1.Follow Control Board Replacement removal instructions, steps
2.Disconnect green ground wire (G) from sprayer by loosening grounding screw (31).
Power Cord Replacement
Installation
1.Follow Control Board Replacement installation instructions, steps
2.Reconnect, green ground wire (G) to green ground- ing screw (31) on frame. Be sure terminal on ground faces UP or wires could get caught in shroud.
3.Reattach motor connector (B) and pressure control switch connect (A).
4.Install shroud (29) and two screws (30).
33
33
240V120V
G
31
26 | 310824D |