Graco Inc 1595 Premium Hi, 795 Premium Hi, 695 Premium Hi, Mark V Switch Tip Installation, Spray

Page 11

Switch Tip Installation

1.Use spray tip (A) to insert OneSeal(B) into guard (C).

C

B A

ti13023a

2. Insert Switch Tip.

ti13024a

3. Screw assembly onto gun. Tighten.

ti2710a

Switch Tip Installation

Spray

1.Spray test pattern. Increase pressure to eliminate heavy edges. Use smaller tip size if pressure adjust- ment can not eliminate heavy edges.

ti13030a

2.Hold gun perpendicular, 10-12 in. (25-30 cm) from surface. Spray back and forth. Overlap by 50%. Trig- ger gun after moving and release before stopping.

ti13025a

Clearing Tip Clog

1.Release trigger, put safety ON. Rotate SwitchTip. Take safety OFF. Trigger gun to clear clog. Never point gun at your hand or into a rag!

ti10166a

ti13033a

ti10167a

2.Put safety ON. Return SwitchTip to original position. Take safety OFF and continue spraying.

ti10166a

ti13034a

ti10167a

3A0156A

11

Image 11
Contents 3A0156A Electric Airless SprayersUltra MAX lIl ModelsGrounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Pails GroundingPressure Relief Procedure Setup 15sec StartupSpray Switch Tip InstallationFast Flush WatchDog ProtectionHose Reel Not Available on All Units Digital Tracking System Not Available on All Units Code Number Models Cleanup Pump Armor Dimensions Technical Data3A0156A For Graco Canada Customers Warranty