Graco Inc Mark V, 795 Premium Hi, 695 Premium Hi, 3A0156A, ti14838a, ti15034a, ti15035a Setup

Page 9

Setup

1.Standard Units Only: Connect Graco airless hose to sprayer. Tighten securely.

ti14843a

2.Standard Units Only: Connect other end of hose to gun and tighten securely.

ti13031a

3. Engage gun trigger safety.

ti10166a

4. Remove tip guard.

ti2769a

5. Check inlet strainer for clogs and debris.

Setup

6.Fill throat packing nut with Graco TSL to prevent premature packing wear. Do this each time you spray.

ti13453a

7. Turn power OFF.

ti4265a

ti4265a

8.Plug power supply cord into a properly grounded electrical outlet.

ti2810a

9. Turn prime valve down to DRAIN position.

ti14842a

10.Place pump in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Perform steps 1 - 5 of Startup to flush out storage oil shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base paint and storage oil.

ti14844a

3A0156A

9

Image 9
Contents 3A0156A Electric Airless SprayersUltra MAX lIl ModelsGrounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Pails GroundingPressure Relief Procedure Setup 15sec StartupSpray Switch Tip InstallationFast Flush WatchDog ProtectionHose Reel Not Available on All Units Digital Tracking System Not Available on All Units Code Number Models Cleanup Pump Armor Dimensions Technical Data3A0156A For Graco Canada Customers Warranty